background image

10 

 

Example#3 

based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

                                                                                                                                                                                                              MaxTime 

 

 

 

 

         

sleeping                          sleeping

 

                ...

 

 

 

0H

                          15

th

 M                       

30

th

 M 

                    45

th

 M                            1H   

1H 10

th

 M

          1H 25

th

 M                      1H 40

th

 M                1H 55

th

 M             

2H 10

th

 M

                                       

 

 

 

 

 

Notes : 

1)

 

The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not 

collect data. 

2)

 

The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, 

the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device 

reports according to MaxTime interval. 

3)

 

We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up 

frequently and the battery will be drained soon. 

4)

 

Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another 

cycle of MinTime/MaxTime calculation is started. 

 

 

7. Installation

 

The device needs to be installed when it is powered off and the detected building/pole is in static status. It is recommended to 

install the device horizontally. After the fixation is completed, please power on the device. The device performs offset calibration 

after it has joined the network for one minute. The device needs a period of time to collect the three-axis tilt angle and battery 

voltage of the detected building/telephone pole, and to make reference for the activity threshold, the inactive time, and whether 

the building/telephone pole is tilted. The specific configuration depends on the actual situation. 

Note:   

After the device is turned on, it must be placed horizontally for one minute before using.   

(The purpose is that the device will automatically perform the offset calibration to reduce the error of the detection result.) 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and collects data 

3.5V |3.5-3.6|=0.1 

REPORTS 3.5V 

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data   

3.5V   

Does not report   

Wakes up and 

collects data 3.5V 

Does not report 

 

 

 

 

Wakes up and 

collects data     

3.5V   

Does not report   

 

Wakes up and 

collects data 

REPORTS 3.5V 

Wakes up and 

collects data 

3.6V 

  Does not report   

Users push the button, 

REPORTS 3.5V. 

Recalculate MaxTime. 

 

 

 

Summary of Contents for R718EB

Page 1: ...ietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written perm...

Page 2: ...ActiveThreshold and InActiveThreshold 7 6 2 Calibration 7 6 3 Example of data configuration 7 6 4 Example for MinTime MaxTime logic 9 7 Installation 10 8 Information about Battery Passivation 11 8 1...

Page 3: ...ology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widel...

Page 4: ...can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Battery Life Plea...

Page 5: ...ver joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to sea...

Page 6: ...erval Battery Change 0x01 0 1v Angle Change 0xC8 1 The accuracy is 3 in horizontal position Angle of Three axis If the three axis acceleration of the device exceeds ActiveThreshold and the tilt angle...

Page 7: ...2 Calibration The accelerometer is a mechanical structure that contains components that can move freely These moving parts are very sensitive to mechanical stress far beyond solid state electronics Th...

Page 8: ...e ThresholdReq 0x03 Threshold 2Bytes InActivetime 1Bytes Unit 1s Reserved 5Bytes Fixed 0x00 SetActive ThresholdRsp 0x83 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetActive ThresholdReq 0x04 Reser...

Page 9: ...e 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime dur...

Page 10: ...etected building pole is in static status It is recommended to install the device horizontally After the fixation is completed please power on the device The device performs offset calibration after i...

Page 11: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Page 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...