17
7.2.3 Vibration Sensor Sensitivity Setting
FPort
:
0x07
Description
Cmd
ID
Device
Type
NetvoxPayLoadData
SetShockSensor
SensitivityReq
0x05
0xD2
InternalShockSensor
Sensitivity (1Byte)
0xFF represent disable
ShockSensor
ExternalShockSensor
Sensitivity (1Byte)
0xFF represent disable
ShockSensor
Reserved
(7Bytes,Fixed 0x00)
SetShockSensor
SensitivityRsp
0x85
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
GetShockSensor
SensitivityReq
0x06
Reserved
(9Bytes,Fixed 0x00)
GetShockSensor
SensitivityRsp
0x86
InternalShockSensor
Sensitivity (1Byte)
0xFF represent disable
ShockSensor)
ExternalShockSensor
Sensitivity (1Byte)
0xFF represent disable
ShockSensor)
Reserved
(7Bytes,Fixed 0x00)
Set Internal Vibration Sensor Sensitivity = 3, External Vibration Sensor Sensitivity = 25
Downlink: 05D2031900000000000000 //19(Hex)=25(Dec)
Response:
85D2000000000000000000
(
Configuration success
)
85D2010000000000000000
(
Configuration failure
)
Note:
1. Internal Vibration Sensor Sensitivity default is 0x05, sensitivity range: 0x00 - 0x0A (0~10)
2. External Vibration Sensor Sensitivity default is 0x14, sensitivity range: 0x00 - 0xFE (0~254)
3. 0xFF represent disable vibration sensor
4. The smaller the number, the more sensitive