R315 series is a multi-sensor device of Netvox's Class A type device based on LoRaWAN open protocol. It can be 

mixed with temperature and humidity, illuminance, door magnetism, internal vibration, external vibration, 

infrared detection, emergency button, tilt detection, water leakage detection, glass break, seat occupancy 

detection, dry contact in, DO out related functions (up to 5 types of sensors can be compatible at the same 

time), and compatible with LoRaWAN protocol.

 

 

LoRa Wireless Technology:

 

LoRa is a wireless communication technology dedicated to long distance and low power consumption. 

Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to 

expand the communication distance. Widely used in long-distance, low-data wireless communications. For 

example, automatic meter reading, building automation equipment, wireless security systems, industrial 

monitoring. Main features include small size, low power consumption, transmission distance, anti-interference 

ability and so on.

 

 

LoRaWAN:

 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between 

devices and gateways from different manufacturers. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for R315 Series

Page 1: ...contains proprietary technical information which is the property of NETVOX Technology and is issued in strict confidential and shall not be disclosed to others parties in whole or in parts without wr...

Page 2: ...e MaxTime Data Variation 15 7 2 2 PIR Setting 16 7 2 3 Vibration Sensor Sensitivity Setting 17 7 2 4 Disable Time and Detection Time 18 7 2 5 Buzzer Beep Duration 19 7 2 6 Dry Contact Point Out Type 1...

Page 3: ...nology LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increas...

Page 4: ...sor PIR Emergence Button Light Sensor Temperature and humidity Sensor Vibration Sensor built in Tilt Sensor External Sensor Reed Switch Water Leak Dry Contact In DO out 3V Vibration Sensor external Se...

Page 5: ...s configured the corresponding sensor should be connected according to the configuration If the corresponding sensor is not connected the reported status should be ignored 4 Main Features Compatible w...

Page 6: ...signal will be output to the DO out it is off by default Configurable resend function The reed switch needs to be fixed when used such as the double sided tape 4 Internal Vibration Sensor Detect the...

Page 7: ...arm status No alarm report 0 Alarm report 1 Configurable press duration 8 Tilt Sensor The sensor adopts 45 tilt detection and the initial state of the device is vertical When the inclination angle cha...

Page 8: ...put to the DO out after the dry contact in is triggered 11 Seat Occupancy When the seat occupancy sensor detects that the occupancy status has changed The seat is occupied report 1 The seat is not occ...

Page 9: ...and IRDetectionTime is 5 minutes When PIR seat occupancy is triggered PIR seat occupancy will be turned off for first 70 of IRDisableTime to save power and then turned on for rest 30 of IRDisableTime...

Page 10: ...e stop vibration stop data will be sent 30 seconds after the vibration stops 5 2 3 LastMessageResendtime Applicable sensor Reed switch tilt sensor When the device is triggered quickly additional data...

Page 11: ...batteries are required to supply power at the same time 3 Remove and insert the battery the device memorizes previous on off state by default 4 On off interval is suggested to be about 10 seconds to...

Page 12: ...device is not in the network green indicator remains off Press and hold the key for 2s Turn off the buzzing buzzer Applicable to device with buzzer Press and hold the key for 4s Turn off the infrared...

Page 13: ...tivity 0x14 External Vibration Sensor Sensitivity Range 0x00 0xFE The smaller the number the more sensitive Disabletime 0x001E 30s PIR and Seat Occupancy DisableTime must 5s Detechtime 0x012C 300s PIR...

Page 14: ...enabled BinarySensorReport 2bytes Bit0 PIRSensorState 0b01_ON 0b00_OFF Bit1 EmergenceButtonAlarmState 0b01_Alarm 0b00_NoAlarm Bit2 TiltSensorState 0b01_ON 0b00_OFF Bit3 InternalContactSwitchSensorStat...

Page 15: ...gence Button Bit6 Reed Switch Bit11 Water Leak 7th 8th byte 0012 BinarySensorReport 0x0012 0000 0000 0001 0010 Bin Bit 1 4 1 ON Bit1 Emergence Button Alarm Bit4 Reed Switch Alarm 9th 10th byte 0ADC Te...

Page 16: ...e Change 2bytes Unit 0 01 C Humidity Change 1byte Unit 0 5 Illuminance Change 1byte Unit 1Lux 1 Configure device parameters MinTime 1min MaxTime 1min BatteryChange 0 1v TemperatureChange 10 C Humidity...

Page 17: ...nable Reserved 8Bytes Fixed 0x00 SetPIR EnableRsp 0x83 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetPIR EnableReq 0x04 Reserved 9Bytes Fixed 0x00 GetPIR EnableRsp 0x84 PIREnable 1Byte 0x00_Disabl...

Page 18: ...vityRsp 0x86 InternalShockSensor Sensitivity 1Byte 0xFF represent disable ShockSensor ExternalShockSensor Sensitivity 1Byte 0xFF represent disable ShockSensor Reserved 7Bytes Fixed 0x00 Set Internal V...

Page 19: ...1Byte 0x00_PIRSensor 0x01_SeatSenso Reserved 8Bytes Fixed 0x00 GetIR DisableTImeRsp 0x88 IRDisableTime 2bytes Unit s IRDetectionTime 2bytes Unit s Reserved 5Bytes Fixed 0x00 1 Set PIR Sensor IRDisable...

Page 20: ...000000000000 Response 89D2000000000000000000 Configuration success 89D2010000000000000000 Configuration failure 7 2 6 Dry Contact Point Out Type FPort 0x07 Description Cmd ID Device Type NetvoxPayLoad...

Page 21: ...O NOT report when sensor restore 0x01_DO report when sensor restore Reserved 8Bytes Fixed 0x00 SetRestore ReportRsp 0x8D Status 0x00_success Reserved 8Bytes Fixed 0x00 GetRestore ReportReq 0x0E Reserv...

Page 22: ...MessageR esendtimeReq only used in contactswitch devicetype 0x1F 0xFF Resendtime 1Byte Unit 1s range 3 254s when 0 or 255 no resend default is no resend Reserved 8Bytes Fixed 0x00 SetLastMessageR esen...

Page 23: ...d so on SetButton PressTimeRsp 0x81 Status 0x00_Success 0x01_Failure GetButton PressTimeReq 0x02 Reserved 1Byte Fixed 0x00 GetButton PressTimeRsp 0x82 PressTime 1byte 0x00_QuickPush_Less then 1 Second...

Page 24: ...0ms Set trigger time 100ms Downlink 010064 Response 810000 Configuration success 820100 Configuration failure Note 1 The issuing port is 0x0F 2 Default is 50ms 7 3 Example for MinTime MaxTime logic Ex...

Page 25: ...Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval a...

Page 26: ...face to prevent the device from falling off after a long time use Note 1 Wipe the surface clean before installation to avoid dust on the surface to affect the adhesion of the device 2 Do not install t...

Page 27: ...V No 27 V V V V V No 28 V V V V V No 29 V V V V V No 30 V V V V V No 31 V V V V V No 32 V V V V V No 33 V V V V V No 34 V V V V V No 35 V V V V V No 36 V V V V V No 37 V V V V V No 38 V V V V V No 39...

Page 28: ...V No 76 V V V V V No 77 V V V V V No 78 V V V V V No 79 V V V V V No 80 V V V V V No 81 V V V V V No 82 V V V V V No 83 V V V V V No 84 V V V V V No 85 V V V V V No 86 V V V V V No 87 V V V V V No 88...

Page 29: ...oy batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the boar...