2
.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and should avoid circling. The area of the conduction between
grounding wire and grounding strip should be no less than 25mm
2
.
2.2.5 Device Grounding
Connect the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right of the rear panel, and the power
switch, fuse, power supply socket are just beside ,whose order goes like this, power switch is
on the left ,power supply socket is on the right and the fuse is just between them.
Connecting the Power Cord:
Connect one end to the power supply socket, and the other end to the AC power.
Connecting Grounding Wire:
When the device solely connects to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1
Ω
.
Caution:
Before connecting power cord to the NetUP HDMI Encoder 8x, set the power