NH-800SP 8 PORTS Managed HPNA IP DSLAM USER’S MANUAL Ver_B2
71
enjoy internet service, you must change a Router with higher session numbers to overcome that.
System Diagnostics
Power and Cooling Problems
If the POWER indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet,
power cord, or internal power supply as explained in the previous section. However, if the unit should turn itself off after
running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fan on
back of the unit is unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power
supply may be defective. In this case, contact your supplier for assistance.
Installation
Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g.,
the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are
functioning properly.
Transmission Mode
The selections of the transmission mode for the RJ-45 ports are auto-negotiation using the default method. Therefore, if the Link
signal is disrupted (e.g., by unplugging the network cable and plugging it back in again, or by resetting the power), the port will
try to reestablish communications with the attached device via auto-negotiation. If auto-negotiation fails, then communications
are set to half duplex by default. Based on this type of industry-standard connection policy, if you are using a full-duplex device
that does not support auto-negotiation, communications can be easily lost (i.e., reset to the wrong mode) whenever the attached
device is reset or experiences a power fluctuation. The best way to resolve this problem is to upgrade these devices to version