background image

DIGITAL MULTIMETER OPERATION MANUAL

1. General

The instrument is a pocket digital multimeter, which is used to measure DCV, ACV, and DCA, resistance, diode and continuity  
test. It is an ideal tool for labs, household and wireless enthusiasts. 

2. Safety Notes

1. Do not input a limit value over the range when measuring. 
2. When measuring voltage higher than 36V DCV, 25V ACV, check the connection and insulation of the test leads to avoid  

electric shock. 

3. Keep the test leads away from the testing point when converting function and range. 
4. Don’t add voltage to the input terminal when measuring resistance.

3. Specification

1. General Features
1-1. Displaying: 22mm digit height LCD display. 
1-2. Max. Indication: 1999 (31/2) auto polarity indication.
1-3. Sampling rate: approx. 3 times/ sec
1-4. Over Range Indication: MSD displays "1"
1-5. Low Battery Indication: " 

 

" symbol displays.

1-6. Operation Environment: (0

40) , relative humidity 

80% .

1-7. Power: 9V battery (NEDA1604/6F22 or equivalent)
1-8. Measurement: 145×85×30mm (Length×Width×Height)
1-9. Weight: Approx. 170g (including a 9V battery)
1-10. Accessories: Operation Manual, Product Certificate, Packing box, Test leads and a 9V battery.
2. Technical Features
Accuracy: ± (a%×d)
Surrounding: (23±5) , relative humidity

75%. One year warranty since the date of manufacture.

2.1 DCV

Range

Accuracy

Resolution

200mV

±(0.5%+4)

100uV

2V

1mV

20V

10mV

200V

100mV

600V

±(1.0%+5)

1V

Input impedance: 1MΩfor all ranges.

2.2 ACV

Range

Accuracy

Resolution

200V

±(1.2%+10)

100mV

600V

1V

Input impedance: 1MΩ. 
Frequency Response: (40

200)Hz

2.3 DCA

Range

Accuracy

Resolution

20uA

±(1.5%+3)

0.01uA

200uA

0.1uA

2mA

1uA

20mA

10uA

200mA

100uA

10A

±(2.0%+5)

10mA

Max. Input current: 10A (no more than 6 seconds)