![Netstor NS388S User Manual Download Page 14](http://html1.mh-extra.com/html/netstor/ns388s/ns388s_user-manual_1674779014.webp)
14
To ensure proper communications between NS388S SAS JBOD enclosure
and the VT-100 Terminal Emulation, please configure the VT100 terminal
emulation settings to the values shown below:
By connecting a VT100 compatible terminal, or a PC operating in an
equivalent terminal emulation mode, all CLI administration functions
can be exercised from the VT100 terminal.
There are a wide variety of Terminal Emulation packages, but for the
most part they should be very similar. The following setup procedure
is an example of setting up VT100 Terminal in Windows O.S. using
Hyper Terminal version 3.0 or higher. For Windows 7, 8.1 or 10, the
HyperTerminal needs to be downloaded; here is the reference site:
http://en.softonic.com/s/hyperterminal-windows-7
The controller RJ11 connector pin assignments are defined as below.
3.1 Expander RS-232C Port Pin Assignment
3.2 Start-up VT100 Screen
Terminal requirement
Connection
Null-modem cable
Baud Rate
115,200
Data bits
8
Stop
1
Flow Control
None
Action
Description
Description
NC
TXD
RXD
GND
Pin
1
2
Pin
3
4