background image

| Industrial 

IoT

4

Device Overview

Cellular antenna 

connector

10-pin NANO-fit (locking) connector 
(power and serial interface)

84 mm

89 mm

50 mm

Summary of Contents for NTC-100

Page 1: ...Quick Start Guide NTC 100 4G LTE Cat M1 NB1 Industrial IoT Serial Modem...

Page 2: ...asily More advanced set up instructions can be found in the user guide which can be downloaded from www netcommwireless com product m2m ntc 100 Package contents The NTC 100 package includes 1 x NTC 10...

Page 3: ...n AC DC power adapter 2 1mm centre positive jack 100 240V AC 12V DC 1 5A used in conjunction with the included Y cable A suitable cellular antenna such as the NANT 00001 000 LTE Tube Antenna A standar...

Page 4: ...Industrial IoT 4 Device Overview Cellular antenna connector 10 pin NANO fit locking connector power and serial interface 84 mm 89 mm 50 mm...

Page 5: ...Industrial IoT 5 NTC 100 4G LTE Cat M1 NB1 Industrial IoT Serial Modem Reset button Network Status SIM card slot Micro USB 2 0 port 21 mm...

Page 6: ...Industrial IoT 6 Installation Connecting the antenna Connect the antenna to the SMA connector on the NTC 100 serial modem by placing it on the SMA connector and turning it in a clockwise direction...

Page 7: ...0 4G LTE Cat M1 NB1 Industrial IoT Serial Modem Inserting the SIM card 1 Lift the cover from the right side This reveals the Micro USB 2 0 port and the reset button 2 Slide the cover to the right to r...

Page 8: ...card in until it locks in place To remove the SIM card push it in again and it will unlock 4 Slide the cover back to the left and then push the right side closed 5 To lock the protective cover fasten...

Page 9: ...s a number of endpoints after the USB port driver is installed Connect a standard USB to USB Micro Type B cable not included between the NTC 100 serial modem and a powered USB port on your device e g...

Page 10: ...s completed install the driver by double clicking on the downloaded file and following the installer prompts 3 Open the Control Panel and then Device Manager The NTC 100 serial modem appears under Por...

Page 11: ...a 4 5 36V power source to the DC Jack to power the unit Connect the 10 pin plug into the 10 pin connector on the NTC 100 serial modem After powering up the NTC 100 serial modem is ready to establish a...

Page 12: ...plies with OK Note that you can access only module AT commands from the USB port If you are accessing the NTC 100 via the Serial Y cable type any character The terminal prompts you for a username and...

Page 13: ...al DIN rail mounting The NTC 100 serial modem mounting bracket has been designed to fit a TS 35 Type O DIN rail with a 25mm core Bend the mounting bracket at the bend line so that the ridges are able...

Page 14: ...uld like to attach the NTC 100 serial modem Attach the mounting bracket to the chosen wall or ceiling by using the 3 screw holes screws not included Pole mounting Use cable ties max 4mm width through...

Page 15: ...erial Modem Inserting the NTC 100 into the mounting bracket Once the bracket is attached to the DIN rail wall or pole snap the NTC 100 into the mounting bracket to hold it in place The NTC 100 can be...

Page 16: ...232 RS 485 RS 422 1 2 Green RXD A RD 2 1 Blue DCD B RD 3 7 Yellow RTS 4 9 Orange RI 5 5 Black GND GND GND 6 4 Brown DTR TD 7 3 White TXD TD 8 6 Purple DSR 9 8 Grey CTS 10 Red DC In DC In DC In Note T...

Page 17: ...Industrial IoT 17 NTC 100 4G LTE Cat M1 NB1 Industrial IoT Serial Modem USB 1 VUSB 5V 2 USB Data N 3 USB Data P 4 USB ID 5 GND...

Page 18: ...TC 100 is powered up and ready for connection Network LED Functions Status Description Off No signal Intermittently Red on 30 seconds off 30 seconds No SIM detected Blinking Red displays red once ever...

Page 19: ...essories Additional cables are available for purchase separately Contact your NetComm Wireless sales representative to order additional cables Refer to the table below for the product codes Accessory...

Page 20: ...peration This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection...

Page 21: ...device transmits This device meets the government s requirements for exposure to radio waves This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency...

Page 22: ...FCC is FREQUENCY MHz GAIN dBi 698 798 4 71 824 960 3 13 1710 2100 3 42 2400 2700 4 32 Company Contact Details NetComm Wireless Limited 1000 Sawgrass Corporate Parkway Suite 500 Sunrise Florida 33323...

Page 23: ...quipement est conforme aux limites d exposition aux rayonnements ISED tablies pour un environnement non contr l This equipment should be installed and operated with minimum distance 20 cm between the...

Page 24: ...ibited for use with this device Les types d antenne non inclus dans cette liste ou dont le gain est sup rieur au gain maximal indiqu sont strictement interdits pour l exploitation de l metteur Antenna...

Page 25: ...Industrial IoT 25 NTC 100 4G LTE Cat M1 NB1 Industrial IoT Serial Modem THIS PAGE INTENTIONALLY LEFT BLANK...

Page 26: ...Industrial IoT 26 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 27: ...Industrial IoT 27 NTC 100 4G LTE Cat M1 NB1 Industrial IoT Serial Modem THIS PAGE INTENTIONALLY LEFT BLANK...

Page 28: ...have any technical difficulties with your product please refer to the support section of our website http support netcommwireless com NETCOMM WIRELESS LIMITED ABN 85 002 490 486 Head Office 18 20 Orio...

Reviews: