14
UPSIDE-DOWN MICRO-EMITTERS
HANDBOOK
EXAMPLE
a
b
c
d
Net application
measurements [mm]
Average net application
of the entire area [AVG]
Average net application of
the lowest 5% [AVG low]
SC value
5.14
91.35 / 20 = 4.57
3.36 / (20 x 5%) = 3.36
(4.57 / 3.36) = 1.36
5.06
5.02
4.99
4.87
4.87
4.83
4.77
4.75
4.73
4.70
4.62
4.41
4.40
4.38
4.26
4.25
4.12
3.82
lowest 5%
3.36
Sum - entire area:
91.35
Sum - lowest 5%:
3.36
Conclusion:
The three instances above demonstrate that each method of calculating distribution
uniformity produces a different result.
Method Value Level of distribution uniformity
%CU
92.12 Very good
%DU
86.65 Very good
SC
1.36 Acceptable for some low value crops
It is common practice among micro-sprinkler/emitter manufacturers to advertise the results of the %CU
method only, which are known to be the most flattering. Netafim™, however, insisting on strict standards
and zealous R&D procedures, tests its micro-sprinklers/emitters with all 3 methods and provides its
customers with the results of the most rigorous analyses.