![Netafim COOLNET PRO Handbook Download Page 35](http://html1.mh-extra.com/html/netafim/coolnet-pro/coolnet-pro_handbook_1669790035.webp)
UPSIDE-DOWN MICRO-EMITTERS
HANDBOOK
35
MICRO-SPRINKLERS/EMITTERS ASSORTMENT
Rooting
For this agricultural application, it is required to create a volume of humidity-saturated air around the
cuttings to facilitate their optimal development.
To achieve this goal, we recommend the CoolNet Pro™ mister.
Installation recommendations for rooting with the cross mister with 4 nozzles of 7.5 l/h each, with a
pressure of 4.0 bar at the nozzles:
1.5 x 1.5 meters, 1.5 meters above the surface. The working pulses should be of 2-3 seconds at a
frequency based on the required relative humidity, controlled by an operator associated with a humidity
sensor.
Humidity increasing
For this agricultural application, it is required to increase the humidity in the structure. For example when
planting/sowing new plants in a relatively cold period, (e.g. usually when the farmer activates the heating
system in the greenhouse and consequently reduces relative humidity through heating).
To achieve this, we recommend the CoolNet Pro™ mister.
Installation recommendations for humidity increasing with the cross mister with 4 nozzles of 5.5 l/h
each, with a pressure of 4.0 bar at the nozzles:
3.0 x 3.0 meters (Can be placed at other distances in the same order of magnitude,
e.g. 2.5 x 3.5 or 2.8 x 3.2 meters), at the maximum height possible above the surface.
Summary of Contents for COOLNET PRO