Control Network
Element Manager User’s Manual Nimbra OneSerie
©2006 Net Insight AB, All rights reserved
Adding a SNMP notification receiver
1.
Navigate to the Control Networks|SNMP page and click on the button
Add SNMP notification receiver. The Add SNMP notification receiver
page, Figure 60, will appear.
Figure 60. Add SNMP notification page
The web page shows information as follows:
•
IP address: The IP address of the configured SNMP notification receiver
(management station).
•
UDP port number: The UDP (user data protocol) port number for the
notification receivers. The standard port number is 162.
2.
Add the IP address and UDP port number for the management station.
3.
Click OK to add the new notification receiver. The Control
Networks|SNMP configuration page will be loaded updated with the new
notification receiver.
Editing or deleting a SNMP notification receiver
1.
Navigate to the Control Networks|SNMP page and click on the IP
address of the notification receiver that should be edited or deleted. The
SNMP notification receiver page, Figure 61, will appear.
Figure 61. Edit SNMP notification page
2.
On this page, the IP address and UDP port number can be changed. To
change the values, edit the IP address and UDP port number for the
management station. The change will be effectuated when the OK or
Apply button is clicked.
3.
To delete the notification receiver, click the Delete button. The Control
Networks|SNMP page will be loaded with the notification receiver
removed.