Element Manager User’s Manual Nimbra OneSerie
Maintenance
•
29
©2006 Net Insight AB, All rights reserved
contents and size of the event and alarm log can be configured, according the
procedure below.
The configurable parameters are:
Parameter name
Description
Type
Visible events
The types of events that the user chooses to
view. The events can be:
performance:
reset:
info:
config:
debug: Not applicable
alarm:
Rec
Visible alarms
The categories of alarms.
Acknowledged: The severity acknowledged
indicates that the alarm is taken care of.
Warning: The warning severity level indicates
the detection of a potential or impending
service affection fault, before any significant
effects have been felt.
Major: The major severity level indicates that a
service affecting condition has developed and
an urgent corrective action is required.
Minor: The Minor severity level indicates the
existence of a non-service affecting fault
condition and that corrective action should be
taken in order to prevent a more serious fault.
Critical: The critical severity level indicates that
a service affecting condition has occurred and
an immediate corrective action is required.
Rec
Event log size
The number of events to keep in the log and
presented for the operator.
Note! The log cannot contain more events than
set in the Systems page
.
Rec
Auto refresh
The refresh interval of the alarm list
information.
Rec
Type definitions:
Man – mandatory, Rec – recommended, Opt – optional
Note:
The event log can not contain more events than what is set in
the System page, Refer to section Setting of system parameters.