User  manual

.9.

.10.

1 2
3 4
5 6
7 8

9 0

#

For a 

PIN

 user

To unlock the door

10.2  Door Relay, Door Open Detection, Alarm, Facility code Settings

Door relay time setting

To disable door open detection.

 (Factory default setting)

 6   0   # 

To enable door open detection

 6  2  # 

Keypad Lockout

Alarm Output

To remove the alarm

To reset the Door Forced Open warning

Normal status: No keypad lockout

 or alarm

 7   0   # (Factory default setting)

 7   1   # 

 7   2   # 

 Read valid card

 or 

Master Code #

To add and delete users in card and PIN mode (   3   1   #   )

.7.

.8.

To exit from the programming mode

To change the master code

To add a 

PIN

 user 

*

Master code #

888888 is the default factory master code

To enter the programming mode

*

Note that to undertake the following programming the master user must be logged in

The master code is any 6 digits

The ID number is any number between 1 ~ 2500. 

The PIN is any four digits between 0000 ~ 9999 

with the exception of 1234 which is reserved. 

Users can be added continuously without exiting

programming mode

W1/W3-B Quick Reference Programming Guide

To add a 

card

 user 

Cards can be added continuously without 

exiting from programming mode

To delete a 

PIN

 or a 

card

 user 

Users can be deleted continuously without

exiting from programming mode

1    Read Card    #

Present the card 

To Unlock the door

Waterproof

Keypad/Reader/Controller

To Add a 

card

 and 

Pin

 user

(The PIN is any four digits between 

0000 ~ 9999 with the exception of 

1234 which is reserved.)

To  change  a 

PIN

in  card  and  PIN

mode  (Method  1)  Note  that  this  is 

done  outside  programming  mode

so  the  user  can  undertake  this

themselves

To  change  a 

PIN

in  card  and  PIN

mode  (Method  2)  Note  that  this  is 

done  outside  programming  mode

so  the  user  can  undertake  this

themselves

To delete a 

Card and PIN

user just 

delete the card

*  Read Card  Old PIN #   New PIN #   New PIN #

*  ID number#  Old PIN #  New PIN #  New PIN #

2  User ID   #

To add a card user in card only mode (  3    0   #   )

ToAdd and Delete a

card

 user

The operating is the same as adding and deleting

a card user in 3   2   #

To delete All users

To add and delete card users by Manager cards

To  delete

  ALL  users. 

Note  that 

this is a

dangerous

 option so use 

with care

To add card user by Manager Add Card

To  delete  card  User  by Manager

Delete Card

2   0000   #

Manager add card   Read card   Manager add card

Cards can be added continuously.

Manager delete card     Read Card   Manager delete card

Cards can be deleted continuously.

Enter the PIN  then press #

For a 

card

 user

Read card

For a 

card and PIN

 user

Read card then enter PIN #

Door relay time setting

4   0~99   #

The door relay time is between 0~99 seconds,

 the factory default setting is 5 seconds.

Door Open Detection

Door Open Too Long (DOTL) warning

. When used with an optional magnetic contact

or built-in magnetic contact of the lock, if the door is opened normally, but not closed 

after 1 minute, the inside buzzer will beep automatically to remind people to close 

the door and continue for 1 minute before switching off automatically.

Door Forced Open warning. 

When used with an optional magnetic contact or built-in

magnetic contact of the lock, if the door is forced open, or if the door is opened after

20  seconds  of  the  electro-mechanical  lock  not  closed  properly,  the  inside  buzzer 

and alarm output will both operate. The Alarm Output time is adjustable between 0-3 

minutes with the default being 1 minute.

Alarm output time

To set the alarm output time (0~3

minutes) Factory default is 1 minute

9   0 3   #

Keypad  Lockout  & Alarm  Output  options

.  If  there  are  10  invalid  cards  or  10

incorrect  PIN  numbers  in  a  10  minute  period  either  the  keypad  will  lockout  for  10

minutes or the alarm will operate for 10 minutes, depending on the option selected 

below.

To reset the Door Open Too Long warning

To set the facility code

Close the door

or

 Read valid card

 or

Master Code #

To set the facility code of W1/W3-

B

(This operation might be required 

when  W1/W3-B  is  acting  as 

wiegand reader and connecting to 

8   Facility code   #   Repeat Facility code  #

Facility  Code  can  be  any  number  between 

1~255   (Default: 0)

11 Interconnecting Two Devices

11.1 W1/W3-B operating as a Wiegand Output Reader

In this mode the W1/W3-B supports a Wiegand 26 bit output so the Wiegand data lines 

can be connected to any controller which supports a Wiegand 26 bit input. See figure 1.

• •

• •

• • • • • •

• • • •

• • • •

W1/W3-B

• • •

• • • • •

• • • • •

• •

• • •

• •

Controller

• •

• •

• • •

• • •

• •

• •

Power

Green

White

Grey

Yellow

Brown
Red

Black

Blue

Purple

Orange

Pink

(With Wiegand 26 inPut)

Transmission Format:

 1: Keypad Transmission

The Reader will transmit the PIN data when it receives the last key (#) press after 

PIN code.

Format:

 Facility Code + PIN Code 

(Facility code is any digits between 0~255, factory default is 0; Pin code is any 1~4

digits between 0~9999)

Example:

 Facility code: 1

                  PIN code: 5678

Press 5678 #, then the output format will be: 00105678

 2: Proximity Card Transmission

The Reader will transmit the card data when it reads the Card.

Format:

 Card Number (the last 8 digits of Card Number)

Remarks: No matter the card or pin is valid or invalid, the data will be transmitted

11.2  W1/W3-B operating as a Controller

In this mode the W1/W3-B supports a Wiegand 26 bit input so an external Wiegand

device with a 26 bit output can be connected to the Wiegand input terminals on the 

W1/W3-B. Either an ID card reader (125KHZ) or an IC card reader (13.56MHZ) can 

be connected to the W1/W3-B. Cards are required to be added at the external reader,

except where an external EM reader is used, in this case cards can be added at either 

reader or controller. See figure 2.

• •

• •

• •

• •

• • • • • •

• • • •

• • • •

• •

• • •

W1/W3-B

Door detecting switch

Special Power Supply

Alarm

• • •

• • • • •

• • • • •

• •

• • •

• •

• •

• ••

• • • • • • • ••

• •

• • •

• •• •

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

Pink

Exit button

Wiegand reader

Fail-Secure lock

Fail-Secure lock

1    User ID number      #     PIN    # 

Add the card as for a card user 
Press

 *

  to 

exit from the programming mode

Then allocate the card a PIN as follows:

*    Read Card    1234 #   PIN #   PIN #

W1-B

Summary of Contents for W1-B

Page 1: ...Waterproof Keypad Reader Controller ey press after incode is any 1 4 ill be transmitted o an external Wiegand input terminals on the eader 13 56MHZ can at the external reader can be added at either al Power Supply Alarm cure lock W1 B ...

Page 2: ... the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2011 Ness Corporation Pty Ltd ABN 28 069 984 372 www ness com au Head Office Ness Corporation Pty Ltd ABN 28 069 984 372 Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au Sydney Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au Melbour...

Page 3: ...D Two W1 W3 B is single door multifunction access controller or a Wiegand output keypad or card reader Itis suitable for mountingeither indoor or outdoorin harsh environments It is housed in a strong sturdy and vandal proof Zinc Alloy electroplated case The electronics are fully potted so the W1 W3 B is waterproof and conforms to IP68 The W1 W3 B supports upto 2500 users ineither a Card 4digit PIN...

Page 4: ...Current Idle Current Lock Output Load Alarm Output Load 5 Installation Remove the back cover from the keypad using the supplied security screwdriver Drill 4 holes on the wall for the screws and I hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the keypad to the back cover Grey Yellow Brown Red Black Blue Purple White C...

Page 5: ...t PowerInput PowerInput Connection Diagram The W keypad Alarm Negative Orange NC Pink GND t output 1 Green D1 12V DC Relay NO Relay COM Relay NC W1 W3 B Negative DC 12VDC 3A Door Switch Exit Button Green White Grey Yellow Brown Red Black Blue Purple Orange Power Alarm Pink Lock Power Electric boltNC Electric strikeNO Power Alarm Common Power Supply Notes Conne Conne To rese hear tw turn in read t ...

Page 6: ...Purple Orange Pink Alarm Power Fail secure lock Alarm Special Power Supply Notes Connect the negative poleof the lock toNC is for Failsafe lock Connect the negative poleof the lock toNO is for Fail secure lock To reset to factory default power off press hold it and power on release it until hear two beeps and the LED shines in orange then read any two EM cards the LED will turn in red means reset ...

Page 7: ...default factory master code To enter the programming mode Note that to undertake the following programming the master user must be logged in 0 New code New code The master code isany 6 digits To add Stand by Setting the working mode 3 0 3 1 3 2 Entry is byeither Cardor PIN default In the programming mode Exit from the programmingmode Open the door 5 To De To cha Note T program Bright Bright Alarm ...

Page 8: ...sing ID number auto generation 1 Read Card Cards can beadded continuously without exiting programming mode 1 ID number Card To add a card user Method 2 This is the second way to enter cards using User ID Allocation In this methoda User IDis allocated to a card Only one user ID can be allocated to a single card Ring r ting Card quantity is between 1 2500 The 8 digits card number is the last 8 digit...

Page 9: ...IN ID number OldPIN New PIN New PIN 2 User ID To add acard user in cardonly mode 3 0 ToAdd and Delete acard user The operating isthe same asadding and deleting a card user in 3 2 To delete All users To add anddelete card users byManager cards To delete ALL users Note that this is a dangerous option so use with care Toadd card userby ManagerAdd Card To delete card User by Manager Delete Card 2 0000...

Page 10: ... not closed after 1 minute theinside buzzer will beepautomatically to remind peopleto close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 20 seconds of the electro mechanical lock not closed properly the insi...

Page 11: ...d reader and connecting to 8 Facility code Repeat Facility code Facility Code can be any number between 1 255 Default 0 11 Interconnecting Two Devices 11 1 W1 W3 B operating as a Wiegand Output Reader In this mode the W1 W3 B supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input See figure 1 W1 W3 B Controller Power Gree...

Page 12: ...mber Remarks No matter the card or pin is valid or invalid the data will be transmitted 11 2 W1 W3 B operating as a Controller In this mode the W1 W3 B supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the W1 W3 B Either an ID card reader 125KHZ or an IC card reader 13 56MHZ can be connected to the W1 W3 B Cards ar...

Page 13: ...ur digits between 0000 9999 with the exception of 1234 which is reserved Users can beadded continuously without exiting programming mode W1 W3 B Quick Reference Programming Guide To add a card user Cards can be added continuously without exiting from programming mode To delete aPIN or a card user Users can be deleted continuously withou t exiting from programming mode 1 Read Card Present the card ...

Reviews: