background image

7

1. Packing list

Name

Digital Keypad W1/W3-B

Quantity

Remark

Screw driver
Rubber  bungs
Self Tapping Screws
Manager Card

1

    4

4
2

6*27mm, used for fixing

3.5*27mm, used for fixing

Manager Add Card & Manager Delete Card

User Manual

1

1

Please ensure that all the above contents are correct. If any are missing please notify 

the supplier of the W1/W3-B. 

2. Description 

3. Features

Waterproof, conforms to IP68 

Strong Zinc Alloy Electroplated anti-vandal case

Full programming from the keypad

2500 users, supports Card, PIN, Card + PIN

Can be used as a stand alone keypad

Programmable one relay output

Backlight keypad

Wiegand 26 input & output

Adjustable Door Output time, Alarm time, Door Open time 

Block enrollment, can enroll maximum 2500 consecutive card within 3 minutes

Very low power consumption (60Ma)

Fast operating speed, <20ms with 2500 users

Easy to install and program

Built in light dependent resistor (LDR) for anti tamper

4. Specifications 

12~24V  AC/DC
2500
12 keys, 2 x 6 digits(W1-B)
12 keys, 3 x 4 digits(W3-B)
EM 125 KHZ card/Tag
3~6 cm

80mA
40mA

Max 2A
Max 20A

Operating Humidity 
Environment
Adjustable Door Relay time
Adjustable Alarm Time

Wiring Connections

Dimensions

Net Weight 
Gross Weight

5%~ 95% RH
Conforms to IP68
0~99 seconds
0~3 minutes

Electric Lock, Exit Button, 
DOTL, External Alarm

550 g
700 g

Operating Voltage
User Capacity

Keypad

Card Type
Card Reading Distance
Active Current
Idle Current
Lock Output Load
Alarm Output Load

5.

Installation

Remove the back cover from the keypad using the supplied security screwdriver

Drill 4 holes on the wall for the screws and I hole for the cable

Fix the back cover firmly on the wall with 4 flat head screws

Thread the cable through the cable hole

Attach the keypad to the back cover.

6. Wiring

Colour

Grey
Yellow
Brown
Red
Black
Blue
Purple

Function

D0

Alarm -
OPEN
D-IN

 12~24V AC&DC

NO
COM

Description

Wiegand Output D0

White

Wiegand Output D1 

Request to Exit Button
Door Contact
12~24V AC&DC Power Input
12~24V AC&DC Power Input

Connection Diagram 

8. Anti Tamper Alarm

The  W1/W3-B  uses  a  LDR  (light  dependent  resistor)  as  an  anti  tamper  alarm.  If  the

keypad is removed from the cover then the tamper alarm will operate.

9.  Sound and Light indication

Operation Status

Power on

Operation successful
Operation failed
Enter into programming mode

Red Light

Bright
Bright
-
-
-
Bright

Green Light

-
-
-
Bright
-
-

Blue Light

-
-
-
-
-
-

Buzzer

Short Ring
-
Short Ring
Short Ring
3 Short Ring
Short Ring
-
Short Ring
-

Press keypad

-

-
-

-
Bright

10. W1/W3-B Detailed Programming Guide

10.1 User Settings

To exit from the programming mode

To change the master code

Set valid card only users

Set valid card

 and 

PIN users

Set valid card 

or

PIN users

*

Master code

#

888888 is the default factory master code

To enter the programming mode

*

Note that to undertake the following programming the master user must be logged in

0   New code    #   New code    #

The master code is any 6 digits.

To add a 

PIN

 users

 1  User ID number   #   PIN   # 
The  ID  number  is  any  number  between  1  ~
2500. The PIN is any four digits between 0000
~  9999  with  the  exception  of  1234  which  is
reserved.  Users  can  be  added continuously
without  exiting  from programming mode as
follows:

 1   User ID No 1   #   PIN   #  User ID No 2   #   PIN   #

Operating Temperature -25 60

Alarm Negative 

Orange

NC

Pink

GND

Stand by

Setting the working mode:

3 0 #

3 1 #

3 2 #

Entry is by either Card

 or 

PIN (default)

.2.

1 2
3 4
5 6
7 8

9 0

#

In the programming mode

Exit from the programming mode

Open the door

.4.

.6.

.5.

To Delete a 

PIN

 user

To change the 

PIN

of a PIN user 

(Note:This step must be done out of 
programming mode)

 *     ID number #   Old PIN #   New PIN #   New PIN #

 2  User ID number  #
Users  can  be  deleted  continuously  without
exiting programming mode

7. To Reset to Factory Default

Bright
-
-
Bright

Alarm

.1.

To add a 

card

 user (Method 1)

This is a fast way to enter cards
 using ID number auto generation.

1   Read Card    #
Cards can be added continuously without exiting 

programming mode

1   ID number   #   Card   #

To add a 

card

 user (Method 2)

This is the second way to enter 

cards using User ID Allocation.

In this method a User ID is allocated

to a card. Only one user ID can be

allocated to a single card.

Built in buzzer

Red, Yellow and Green LEDs display the working status

12~24V AC/DC

Two- year warranty

W1/W3-B is single door multifunction access controller or a Wiegand output keypad or 
card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It
is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case. 
The electronics are fully potted so the W1/W3-B is waterproof and conforms to IP68. 
The W1/W3-B supports up to 2500 users in either a Card, 4 digit PIN, or a Card + PIN 
option. The inbuilt card reader supports EM, 125KHZ frequency card/Tag. The W1/W3-
B has m any extra features including block enrollment,wiegand 26 bits interface, and backlit 
keypad...etc.
These features make the W1/W3-B an ideal choice for door access not only for small
shops and domestic households but also for commercial and industrial applications 
such as factories, warehouses, laboratories, banks and prisons.

Wiegand Interface 

Wiegand 26 input & output

PCB connect diagram

Anti-demolition alarm

••

••

••

••

••

••

••

••

••

••

••

••

••

••

••

••

••

J1

••

••

••

••

••

••

••

••

••

••

••

••

••

••

••

••

••

J1

Green

D1

 12~24V AC&DC

Relay NO 
Relay COM
Relay NC
W1/W3-B Negative

• •

• •

• • • • • •

• • • •

• • • •

AC&DC

12 24V/3A

Door 

Switch

Exit

Button

Door 

Switch

Exit

Button

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

Power

Alarm

• • •

• • • • •

• • • • •

• •

• • •

• •

Pink

Lock

••

••

••

Power +

Electric boltNC

Electric strikeNO

Power +

Alarm -

Common Power Supply

• •

• •

• • • • • •

• • • •

• • • •

• •

• • •

• • • • • • • •• •

• • • • • • • •• •

• • •

• • • • •

• • • • •

• •

• • •

• •

• •

• • •

• •

• • • • • • • • • • •

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

Pink

Alarm

Power

Fail-secure lock

Alarm-

Special Power Supply

Notes:

Connect the negative pole of the lock to NC is for Fail safe lock.

Connect the negative pole of the lock to NO is for Fail-secure lock. 

To reset to factory default, power off, press  *  , hold it and power on, release it until 

hear two beeps and the LED shines in orange, then read any two EM cards, the LED will

turn  in  red,  means  reset  to  factory  default  setting  successfully.  Of  the  two  EM  cards 

read,  the  first  one  is  Manager  Add  card,  the  second  one  is  Manager  Delete  card.

-
-

-
-

Alarm

Bright
-

-
-

Short Ring

Entry is by Card only

Entry is by Card 

and

 PIN together

To add and delete users in either card or PIN mode   ( 3   2   # ) (Default setting)

Card quantity is between 1~2500.

The 8 digits card number is the last 8 digits on

 the card.

Maximum 2500 cards can be enrolled at a stretch

within 3 minutes.

To add

card

 user (Method 3)

Add a 

series cards

 users

Block Enrollment

To delete

card

 user by card

number.

Note Users can be deleted 

continuously without exiting

from programming mode.

2   Read Card    #

5    ID number   #     8 digits Card number   #    Card quantity   #

To  delete  a 

card

user  by  user  ID.

This  option  can  be  used  when a

user has lost their card

2   User ID    #

.3.

Remarks:

 Reset to factory default, the user's information is still retained. 

(W1-B&W3-B are in the same function, only different in shape  . )

L135 x W58 x H26 mm(W1-B)
L128 x W82 x H28 mm(W3-B)

W1-B

Summary of Contents for W1-B

Page 1: ...Waterproof Keypad Reader Controller ey press after incode is any 1 4 ill be transmitted o an external Wiegand input terminals on the eader 13 56MHZ can at the external reader can be added at either al Power Supply Alarm cure lock W1 B ...

Page 2: ... the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2011 Ness Corporation Pty Ltd ABN 28 069 984 372 www ness com au Head Office Ness Corporation Pty Ltd ABN 28 069 984 372 Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au Sydney Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au Melbour...

Page 3: ...D Two W1 W3 B is single door multifunction access controller or a Wiegand output keypad or card reader Itis suitable for mountingeither indoor or outdoorin harsh environments It is housed in a strong sturdy and vandal proof Zinc Alloy electroplated case The electronics are fully potted so the W1 W3 B is waterproof and conforms to IP68 The W1 W3 B supports upto 2500 users ineither a Card 4digit PIN...

Page 4: ...Current Idle Current Lock Output Load Alarm Output Load 5 Installation Remove the back cover from the keypad using the supplied security screwdriver Drill 4 holes on the wall for the screws and I hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the keypad to the back cover Grey Yellow Brown Red Black Blue Purple White C...

Page 5: ...t PowerInput PowerInput Connection Diagram The W keypad Alarm Negative Orange NC Pink GND t output 1 Green D1 12V DC Relay NO Relay COM Relay NC W1 W3 B Negative DC 12VDC 3A Door Switch Exit Button Green White Grey Yellow Brown Red Black Blue Purple Orange Power Alarm Pink Lock Power Electric boltNC Electric strikeNO Power Alarm Common Power Supply Notes Conne Conne To rese hear tw turn in read t ...

Page 6: ...Purple Orange Pink Alarm Power Fail secure lock Alarm Special Power Supply Notes Connect the negative poleof the lock toNC is for Failsafe lock Connect the negative poleof the lock toNO is for Fail secure lock To reset to factory default power off press hold it and power on release it until hear two beeps and the LED shines in orange then read any two EM cards the LED will turn in red means reset ...

Page 7: ...default factory master code To enter the programming mode Note that to undertake the following programming the master user must be logged in 0 New code New code The master code isany 6 digits To add Stand by Setting the working mode 3 0 3 1 3 2 Entry is byeither Cardor PIN default In the programming mode Exit from the programmingmode Open the door 5 To De To cha Note T program Bright Bright Alarm ...

Page 8: ...sing ID number auto generation 1 Read Card Cards can beadded continuously without exiting programming mode 1 ID number Card To add a card user Method 2 This is the second way to enter cards using User ID Allocation In this methoda User IDis allocated to a card Only one user ID can be allocated to a single card Ring r ting Card quantity is between 1 2500 The 8 digits card number is the last 8 digit...

Page 9: ...IN ID number OldPIN New PIN New PIN 2 User ID To add acard user in cardonly mode 3 0 ToAdd and Delete acard user The operating isthe same asadding and deleting a card user in 3 2 To delete All users To add anddelete card users byManager cards To delete ALL users Note that this is a dangerous option so use with care Toadd card userby ManagerAdd Card To delete card User by Manager Delete Card 2 0000...

Page 10: ... not closed after 1 minute theinside buzzer will beepautomatically to remind peopleto close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 20 seconds of the electro mechanical lock not closed properly the insi...

Page 11: ...d reader and connecting to 8 Facility code Repeat Facility code Facility Code can be any number between 1 255 Default 0 11 Interconnecting Two Devices 11 1 W1 W3 B operating as a Wiegand Output Reader In this mode the W1 W3 B supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input See figure 1 W1 W3 B Controller Power Gree...

Page 12: ...mber Remarks No matter the card or pin is valid or invalid the data will be transmitted 11 2 W1 W3 B operating as a Controller In this mode the W1 W3 B supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the W1 W3 B Either an ID card reader 125KHZ or an IC card reader 13 56MHZ can be connected to the W1 W3 B Cards ar...

Page 13: ...ur digits between 0000 9999 with the exception of 1234 which is reserved Users can beadded continuously without exiting programming mode W1 W3 B Quick Reference Programming Guide To add a card user Cards can be added continuously without exiting from programming mode To delete aPIN or a card user Users can be deleted continuously withou t exiting from programming mode 1 Read Card Present the card ...

Reviews: