2
InstallatIon & testIng
1 Unclip the bottom of the lid and swing it open.
2 To remove the circuit board, press the left side Locking
Clip and push the board up to clear the two bottom
retaining hooks. Slide the board up and out of the base.
3 The base can be corner or flat surface mounted. Drill
holes as required for mounting and mount the base
securely filling any gaps or holes with a flexible sealant
such as silicone.
4 Replace the board and ensure the mounting height
adjustment is set correctly.
5 Wire the detector appropriately as shown in the Wiring
Diagram.
6 Set the COUNT link to suit your application (see Links).
7 Replace the cover, top clip first. If the cover needs
to be screw secured, use the screw provided.
Do Not Overtighten. Cover the screw with the screw
cap provided.
8 Wait approximately 60 seconds for the detector to
‘warm up’. The red Alarm LED will flash during this
period.
9 Walk test the PIR coverage by walking slowly across
the protected area. The green PIR LED should indicate
detection at a maximum of 3 to 4 walking steps at a
distance of 10m from the detector.
10 Walk test the Microwave coverage at the extremity of
the area to be covered. Using the amber Microwave
LED as your guide, adjust the MICROWAVE RANGE
control (VR1) so that the microwave is just detecting
you at this point.
11 Always use the lowest MICROWAVE RANGE and
highest COUNT setting for any given area. Avoid
the possibility of false alarms caused by setting the
detector too sensitive for the environment.
CONTROL
PANEL
0V
ALARM
TAMPER
N.C.
N.C.
+12V
N.C.
N.C.
NESS QUANTUM DETECTOR
(all models)
Zone
Zone
TAMP
0V
C
C
C
Optional Tamper wiring
+12V
2K2
2K2
WIrIng
2.1m
1.1m
MIN
MAX
LEDS
COUNT
0V
+12V
ALARM
TAMPER
MICROWAVE RANGE
adjustment
LED link
COUNT link
PYRO sensor
(DO NOT TOUCH)
TAMPER
switch
Board
Locking Clip