Dimensions 

123 x 70 x 50mm

Mounting height 

2.1m (Min) ~ 3.1m (Max)

Coverage 

12m x 12m @ 90°

PIR Detector zones 

20 dual element zones

Pulse count 

Selectable 1~2 or 3~4

Microwave Range 

Selectable Low/high

Pet Immunity 

Single pet up to 25kg or multi-
ple pets up to 15kg total

PIR Sensor 

Dual element pyroelectric

Microwave frequency  10.525 Ghz
Visual display 

Green: PIR LED

 

Amber: Microwave LED

 

Red: Alarm LED 

Alarm period 

2 seconds

Warm up period 

60 seconds

Alarm output 

Normally Closed relay (fail 
safe) dry contacts with 47 
Ohm resistor in series

Tamper output 

Normally Closed dry contacts 
with 47 Ohm resistor in series

Operating voltage 

9~15V DC

Current draw 

20mA, (28mA Walk Test)

Operating temperature  0~50°C
Operating humidity 

Up to 95% Relative humidity 
(non condensing)

sPecIFIcatIons

Program lInks

COUNT

:

 

COUNT link selects two pulse count positions.

COUNT LINk ON: 1~2 Pulses or walk steps should cause 
an alarm.

COUNT LINk Off: 3~4 Pulses or walk steps should 
cause an alarm.

DOCUMENT PART NUMBER 890-258
for products: 100-694 Ness Pet Aware DUAL 

© 2011 Ness Corporation Pty Ltd ABN 28 069 984 372

Specifications may change without notice.

The cOuNT link musT be in the Off 
position when protecting an area with 
a pet weighing mOre than 10kg. 

MICROWAVE RANGE

:

The  MICROWAVE RANGE rotary control (VR1) selects 
low~high microwave range.

ANTICLOCkWISE: Decrease microwave range
CLOCkWISE: Increase microwave range

The  MICROWAVE RANGE control should be set to the 
minimum setting that  will adequately cover the protected 
area.

LEDS

:

 

The LEDS link disables all LEDs. Default position is ON.

Summary of Contents for Quantum Pet aware Dual

Page 1: ... your pets indoors Designed for use with a single pet weighing up to 25kg in weight can be used with multiple pets weighing less than a total of 15kg i e 2 dogs weighing 7kg each for a total of 14kg Quantum Pet aware Dual Features Dual PIR Microwave technology True 12m x 12m wide angle coverage Immune to a single animal up to 25kg Immune to multiple animals up to 15kg High R F and E S D immunity H...

Page 2: ...ely 60 seconds for the detector to warm up The red Alarm LED will flash during this period 9 Walk test the PIR coverage by walking slowly across the protected area The green PIR LED should indicate detection at a maximum of 3 to 4 walking steps at a distance of 10m from the detector 10 Walk test the Microwave coverage at the extremity of the area to be covered Using the amber Microwave LED as your...

Page 3: ...antum Pet sensor is 2 1 to 2 4 metres This height ensures maximum intruder protection whilst still maintaining false alarm immunity from pets Mounting heights above this will markedly reduce the ability of the Quantum Pet sensor to detect an intruder in the region 2 to 3 metres surrounding the detector Designed for installation heights of 2 1m minimum to 3 1m maximum installing the detector lower ...

Page 4: ...g temperature 0 50 C Operating humidity Up to 95 Relative Humidity non condensing Specifications Program Links COUNT COUNT link selects two pulse count positions COUNT LINK ON 1 2 Pulses or walk steps should cause an alarm COUNT LINK OFF 3 4 Pulses or walk steps should cause an alarm DOCUMENT PART NUMBER 890 258 For products 100 694 Ness Pet Aware DUAL 2011 Ness Corporation Pty Ltd ABN 28 069 984 ...

Reviews: