5000 Series Dialler
Page 10
DOUBLE RINGS NEEDED FOR AUTO-ANSWER.
P 48 E number E
This option defines the number of double rings needed to make the Dialler Auto-Answer,
ie. to answer an incoming call. The number may be set from 1 to 15.
The default is 3 double rings
ABORT TIME DELAY for DELAYED DIALLING
P 52 E time E
This Option defaults to 10 seconds but may be set from 1 second to 120 minutes
in the same manner as P42E. To make use of the delay on an alarm,
the ABORT feature must be selected for that alarm.
MEDICAL ALARM TIME DELAY.
P 53 E time E
This option defaults to 0 seconds which means that Medical Alarms from the panel
(1 E) are sent immediately if enabled in the Dialler(P65E).
When the time is other than 0, then alarms are only sent by the Dialler if the
Medical Alarms are NOT received within that time. For example, if the time
is 24 hours then an alarm will be sent if the client does not press 1 E
on the panel every 24 hours. The time may be set from 1 to 250
which represents 0.1 to 250 hours. In this situation, an immediate alarm can
still be sent by pressing l E twice within a 6 minute period.
DIALLER #1 and #2 ALARM REPORTING.
P xx E channel E value E
The 8 Zone Control Panel produces the following 22 alarms which must be assigned
to the 9 channels allowed in a transmission to a Central Monitoring Station.
The channel number can be from 0 to 9 and the current selection
for an alarm is shown via the 8 ZONE indicators, the 9 (BATTERY)
and the 0 (MAINS) indicators. Only one channel may be selected for an
alarm at any one time.
One or more of the three special features explained below may be selected
for each alarm and the current selection is shown via the indicators as follows:
Function
Indicator
Option
ABORT TIME
Arm/Monitor
11
RESTORE
Alarm/Memory
12
MULTIPLE REPORTS
Zone Excluded
13
Thus to set Zone 1 alarm to channel 6 and select all of the three special features,
press the buttons:
P71E
6E
11E
12E
13E
Ie. P 71 E
channel E
abort E restore E
multiple E