Maestria / Gran Maestria service manual
83
R E P A I R S
7.5.5 Replacing milk regulator assembly
•
Unplug connector for milk regulator (821) from electronic mainboard (806).
•
Remove 3 cable clips (111) from holder (1) by pressing the retention latches
inwards.
•
Loosen 3 screws (TX 10) and remove milk regulator (821).
Assembly checkpoint
•
Use cable guides on holder for milk regulator (77) and cable clips (111) to secure
wires.
7.5.6 Reassembly and wiring instructions - Gran Maestria
Reassembly checkpoints
•
Check if light guide (115) is mounted before attaching upper part of housing (114).
•
Check if permanent magnet (142) for drip tray is inserted in base (141). Remove
mounting aid (additional magnet) if present.
•
Take care not to jam any wires between base and upper part (especially wiring of
electronic main board).
821
77
111
Do not lose cable
clips!