15
Digital display code table
Error code
Cause
Solution
E0
System error
Replace the controller
E1
The motor is not connected
Check motor connection
E2
Motor line failure
Check motor connection, replace the motor
E3
Electric lock over current
Check that the electric lock is not short-
circuited and the current does not exceed 1A
E4
Too high DC voltage
Check 12V voltage port input and lock
E5
Too low DC voltage
Check 12V voltage port input and lock
E6
Too high AC voltage
Check voltage
E7
Too low AC voltage
Check voltage
E8
No door was detected
Check the attachment of the pull and push
arm
E9
The door does not close
Check the door, remove obstacles in front of
the door
Summary of Contents for NEO-100