background image

 

13 

www.nerival.fi

 

1: P1 normally open  

P2 close 

2: P1 Point move open-close 

18 

Motor torque 

0-20 

20 

0: minimum 

20: maximum 

19 

Opening delay  

0-85 

Opening delay for synchronization of 

two door operators 

21 

Restore factory 

settings 

0-10 

0: empty 

1: resets settings 1-22 settings to 

factory defaults 

22 

Delete the remote 

controls 

0 or 10 

0: empty 

10: Delete all remote controls 

Advanced settings  
Press the 

 button for five seconds to enter the advanced setting mode.  

Use the 

 and 

 buttons to select the setting you want to set.  

Press the   decrease or   increase button to set the desired value. 
To save the setting and exit the setting mode, press the        button. 

 

Asetuksen 

numero 

Toiminto 

Asetusalue 

Lisätiedot 

27 

Encoder direction 

0-1 

0: normal 

1: reverse 

28 

Type of electric lock 

0-1 

0: power on: locked 

1: power off: locked 

29 

Windproof mode 

0-1 

0: off 

1: windproof 

31 

Protected mode 

0-2 

0: Lock release 

1: Access control 

2: Autoreset 

 

 

Summary of Contents for NEO-100

Page 1: ...1 www nerival fi User manual AUTOMATIC DOOR OPERATOR NEO 100...

Page 2: ...operator 6 Outward opening door Installation with push arm door operator inside 7 Inward opening door Installation with pull arm door operator inside 8 Kytkent 9 Button functions 11 Settings 12 Gener...

Page 3: ...ctrical connections Make sure the power supply is turned off before making any connections This product must be earthed Before turning on the power Ensure correct supply voltage 230VAC Make sure that...

Page 4: ...4 www nerival fi Overview Automatic door operator Accessories Dimensions...

Page 5: ...ngle 45 180 adjustable Supply voltage 230VAC Max power 45W Standby power consumption 2W Remote control distance Over 30m Operating temperature 40 85 Protection class IP41 Dimensions 580mm x 80mm x 90m...

Page 6: ...6 www nerival fi Installation example Installation of mounting plate and door operator...

Page 7: ...7 www nerival fi Outward opening door Installation with push arm door operator inside Loosen the screws to set the push arm at a 90 degree angle to the door...

Page 8: ...8 www nerival fi Inward opening door Installation with pull arm door operator inside...

Page 9: ...L Electric lock output 12VDC L Electric lock output 12VDC GND Voltage output 12VDC 12V Voltage output 12VDC max 500mA P1 Voltage signal 12VDC GND GND P1 Door open signal P2 Door close signal P3 Closin...

Page 10: ...Door close signal The door does not open when the signal is active P3 GND Safety sensor for closing door When the sensor detects the door opens P4 GND Safety sensor for opening door When the sensor de...

Page 11: ...door is closed in the correct position If the device cannot detect the correct stop position the error message E08 is displayed If the door closes in the wrong direction see setting no 9 To skip the...

Page 12: ...has opened 6 Closing door anti collision delay 0 30 10 The smaller the delay the faster the door opens in a collision 7 Closing force 0 10 5 The higher the value the greater the closing force 8 Lock...

Page 13: ...l remote controls Advanced settings Press the button for five seconds to enter the advanced setting mode Use the and buttons to select the setting you want to set Press the decrease or increase button...

Page 14: ...ter increase or decrease button 2 Press any key on the remote control 3 The value of the digital display increases by 1 4 The remote control has been successfully added Repeat the above steps to add m...

Page 15: ...over current Check that the electric lock is not short circuited and the current does not exceed 1A E4 Too high DC voltage Check 12V voltage port input and lock E5 Too low DC voltage Check 12V voltage...

Reviews: