10
NO/COM/NC: Potential-free changeover switch.
P1 +: Door open signal from access control. The input is a voltage signal of 12VDC.
P1/GND: Door open signal. Sensor signal.
P2/GND: Door close signal. The door does not open when the signal is active.
P3/GND: Safety sensor for closing door. When the sensor detects, the door opens.
P4/GND: Safety sensor for opening door. When the sensor detects, the door stops.
P5/GND: Synchronization of two door operators. Both door operators operate
simultaneously.
* Use the included relay card if voltage used for locking is other than 12VDC.