NERI Nebula L Installation Manual Download Page 7

INSTALLATION PROCEDURE

EN

7

neri.biz

7

neri.biz

INSTALLATION INFORMATION

Installation must be carried out in 
accordance with national standards.
The fixture must only be used when 
complete with safety screen. If the screen 
is damaged or broken, the fixture must not 
be used. Restore the original conditions 
before reusing. The fixture is installed 
under CL II protection standards, 
particular care must be taken while 
assembling to ensure that exposed metal 
parts do not come into electrical contact 
with parts of the electrical installation 
connected to a protection conductor. This 
light fixture must be installed only for the 
use for which it was designed, namely for 
the illumination of outdoor spaces. 
Any other use must be considered to be 
improper and dangerous, and the 
manufacturer cannot be held liable for 
any damage caused by improper and 
unreasonable use.
For more information, please see the
supplementary instructions on the
website at

www.neri.biz/installationguides

Handle the products with extreme care as 
impact can cause visible damage.

Installation

Check for proper installation of the pole 
and its components.
The lighting fixture shall be as shown in 
the drawing (Fig. 1).
Unscrew the four nuts (M6), the two flat 
washers and the two serrated washers 
(Fig. 2). Make sure the lighting fixture to be 
installed is as shown in the drawing (Fig. 
3).
Unscrew the six screws (M4) (Fig. 4) and 
remove the three covers in the central part 
of the lighting fixture (Fig. 5).

Adjusting the inclination of the lighting 
fixture

In case of installation with inclination in 
steps of 0°, ±30°, ±45° use the two small 
plates on the lighting fixture to set the 
desired position (Fig.6-7). In case of 
installation with an inclination value 
different from the  proposed standard 
(step 0°, ±30°, ±45°) it is necessary to 
unscrew the four screws (M4) and remove 
the two small plates (Fig. 8-9). The 
permitted free adjustment is ±45° (Fig. 
8-10).
The lighting fixture is equipped with an 

place it in the desired configuration and 
tighten the two screws (M6) (Fig. 34-35).
When configuring with two accessories, 
repeat the above steps.

Refractor Screens

Follow the instructions below to install the 
refractor screens:
Unscrew the end ring located at the end of 
the lighting fixture by means of the two 
screws (M6) (Fig.36).
Place the chosen refractor screen in the 
desired position (Fig. 37) and tighten the 
ring using the two screws (M6) (Fig. 38).

MAINTENANCE

WARNING! 

Disconnect the light fi xture 

from the power supply system.
Maintenance operations must be carried 
out by expert personnel only. These 
operations involve:
• Cleaning the safety shield and external 
structure to remove any material which 
could negatively affect performance: 
(with the appliance closed) use only clean 
water and a sponge (do not use 
high-pressure water jets or other 
cleaning products).
• Checking that the appliance is securely 
fastened to the support (once a year).
During annual inspection operations, 
check the painted surfaces for signs of 
damage such as blistering or cracking. 
Should any such damage be found, 
intervene immediately to restore the 
paintwork. Contact Neri SpA for 
indications and materials to be used for 
retouching the paintwork.

PHOTOBIOLOGICAL RISK

The luminaire should be positioned so
that prolonged staring into the luminaire
at a distance closer than 1,85m [6’ 3/4”] 
(ST version) - 9,49m [31’ 1 2/4”] (PR 
version) - 8,25m [27’ 3/4”] (RGBW 
version).

optical adjustment system.
The light emission of the lighting fixture is 
as shown in the drawing (Fig. 11).
Proceed to Step 3 (Electrical Connection) 
for standard configuration.

Adjusting the optical system of the 
lighting fixture

To change the direction of light emission, 
follow these steps
(Allowable rotation is ±90°) (Fig.12). 
Unscrew the six screws (M4) (Fig. 4) and 
remove the three covers in the central part 
of the lighting fixture (Fig. 5). Unscrew the 
eight nuts (M6) and the four washers
(Fig. 13-14-15). Remove the lighting fixture 
(Fig. 16) and turn it until the desired 
configuration is reached (Fig. 17). 
Reposition the lighting fixture to its 
original position (Fig. 18) and tighten the 
eight nuts (M6) and four washers (Fig.19).
In case of configuration with two light 
sources, repeat the previous steps.

Electrical Connection

Slide the power cord inside the pole until it 
reaches the terminal block (Fig. 20-22-23 
To facilitate the passage of the power 
cord, keep the pole slot aligned with the 
fixing device (Fig. 21).
In case of configuration with two light 
sources, repeat the previous step (Fig. 
20-22-23
In case of RGBW source repeat the 
previous step and connect the DMX cable.
If the external flexible cable of this device 
is damaged
it can be replaced only by the manufactu-
rer, its service agent, or a person qualified 
to do so in order to avoid hazard.
Screw on the four nuts (M6), the two flat 
washers and the two serrated washers 
(Fig. 24). When the operation is complete, 
the lighting fixture must be as shown in 
the drawing (examples with inclination 0° 
and 45° - Fig. 25-26).
Place the three covers in the central part 
of the lighting fixture (Fig. 27) and tighten 
the six screws (M4) (Fig.28). When the 
operation is complete, the lighting fixture 
must be as shown in the drawing (Fig. 29).
In case of configuration with more than 
one lighting fixture, repeat the steps from 
step 1.

Anti-glare devices

For the installation of devices
anti-glare follow the instructions below:
Unscrew the two screws (M6) at the base of 
the lighting fixture (Fig. 30) and remove the 
terminal (Fig. 31). Bring the accessory 
(available in 30° and 45° versions) closer to 
the base of the lighting fixture (Fig. 32-33), 

RISK OF ELECTRIC SHOCK

Summary of Contents for Nebula L

Page 1: ...GUIDA ALL INSTALLAZIONE INSTALLATION GUIDES GUIDE D INSTALLATION INSTALLATIONSANLEITUNG GUÍA DE INSTALACIÓN Nebula L LED Z013 0104 Rev 00 2021 02 10 ...

Page 2: ...hould be read with attention and kept with great care FR Ce manuel doit être lu très attentivement et soigneusement conservé DE Die Anleitung sollte mit gr oßer Aufmer ksamkeit gelesen und aufbewahrt werden ES Este manual se debe leer con detenimiento y conservar cuidadosamente ...

Page 3: ...tará los métodos de instalación correcta de los cuerpos de iluminación siendo una guía para instaladores profesionales Por ello este manual debe leerse con gran detenimiento IT 1 Abbigliamento da lavoro 2 Scarpe antinfortunistiche 3 Casco obbligatorio 4 Guanti da lavoro 5 Danni ai componenti 6 Inquinamento ambientale 7 Nota informativa 8 Verifica tecnica 9 Pericolo per l operatore 10 Rischio fotobi...

Page 4: ...ll apparecchio CONFORMITÀ COMPLIANCE CONFORMITÉ KONFORMITÄT CUMPLIMIENTO DE NORMAS EN Street lighting appliance in compliance with the standards indicated in the table with ENEC15 safety mark or cULus mark NOTE Only those products bearing the ENEC or UL mark should be considered to be listed and covered under follow up service Always look for the mark on the product Specific electrical characterist...

Page 5: ...ral 0 139m2 1 49ft2 Area frontale Front area Zone frontale Bereich vorn Área frontal Area superiore Top area Zone supérieure Oberer Bereich Área superior 0 018m2 0 19 ft2 EPA Peso Weight Poids Gewicht Peso 12 0kg 26 45 lb dthr Nebula LED Cod LUNEB Ø 155 mm 6 900 mm 3 0 139m2 1 49ft2 H installazione H installation H instalación H min 3 0m 9 84ft 1 26ft2 5 neri biz ST 1 85m PR 9 49m RGBW 8 25m ...

Page 6: ...eguenti istruzioni svitare le due viti M6 alla base del corpo illuminante Fig 30 e rimuovere l elemento terminale Fig 31 Avvicinare l accessorio disponibile in versione 30 e 45 alla base del corpo illuminante Fig 32 33 posizionarlo nella configurazione desiderata e avvitare le due viti M6 Fig 34 35 In caso di configurazione con due accessori ripetere i passaggi precedenti Schermi rifrattori Per l in...

Page 7: ...performance with the appliance closed use only clean water and a sponge do not use high pressure water jets or other cleaning products Checking that the appliance is securely fastened to the support once a year During annual inspection operations check the painted surfaces for signs of damage such as blistering or cracking Should any such damage be found intervene immediately to restore the paintw...

Page 8: ...nnel spécialisé et concernent notamment Nettoyage de l écran de protection et de la structure externe pour l élimination de tout éventuel matériel qui pourrait en altérer le fonctionnement avec l appareil fermé uniquement avec de l eau et une éponge ne pas utiliser d hydro nettoyeuses à pression et d autres produits pour le nettoyage Vérification du serrage de l appareil au support une fois par an ...

Page 9: ...mit den beiden Schrauben M6 abschrauben Abb 36 Die ausgewählte Refraktorscheibe in der gewünschten Position bringen Abb 37 und den Ring mit den beiden Schrauben M6 festschrauben Abb 38 WARTUNG ACHTUNG Die Wartungsarbeiten dürfen nur von Fachpersonal ausgeführt werden und betreffen mit das Gerät geschlossen und von der Stromversorgung getrennt Reinigung des Schutzschirms und des äußeren Gehäuses zu...

Page 10: ...s adicionales en el sitio en www neri biz guidainstallazione Instalación Compruebe la correcta instalación del poste y sus componentes El dispositivo de fijación de la luminaria deberá ser como se muestra en el dibujo Fig 1 Desenrosque las cuatro tuercas M6 las dos arandelas planas y las dos arandelas dentadas Fig 2 Compruebe que la luminaria que se va a instalar es la indicada en el dibujo Fig 3 D...

Page 11: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 1 3 2 4 11 neri biz ...

Page 12: ...AZIONE INSTALLATION FIXATION MONTAGE MONTAJE 5 7 6 8 0 30 45 30 45 0 30 45 30 45 0 45 45 12 Neri Spa Guida all installazione Installation guides Guide d installation Installationsanleitung Guía de instalación ...

Page 13: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 9 11 10 12 90 90 0 45 45 13 neri biz ...

Page 14: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 13 14 16 15 14 Neri Spa Guida all installazione Installation guides Guide d installation Installationsanleitung Guía de instalación ...

Page 15: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 17 18 20 19 90 11 Nm 11 Nm 11 Nm 15 neri biz ...

Page 16: ...INSTALLATION FIXATION MONTAGE MONTAJE 21 22 24 23 IP66 L L N N IP66 N N L L GND GND 11 Nm 11 Nm 16 Neri Spa Guida all installazione Installation guides Guide d installation Installationsanleitung Guía de instalación ...

Page 17: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 25 26 28 27 3 25 Nm 3 25 Nm 17 neri biz ...

Page 18: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 29 30 32 31 18 Neri Spa Guida all installazione Installation guides Guide d installation Installationsanleitung Guía de instalación ...

Page 19: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 33 34 35 11 Nm 11 Nm 11 Nm 11 Nm 19 neri biz ...

Page 20: ...INSTALLAZIONE INSTALLATION FIXATION MONTAGE MONTAJE 36 37 38 11 Nm 11 Nm 20 Neri Spa Guida all installazione Installation guides Guide d installation Installationsanleitung Guía de instalación ...

Page 21: ...reproduit même partiellement sans l accord écrit de Neri SpA Neri SpA se réserve le droit d apporter toutes modifications à ses produits et à la documentation sans préavis DE Eine Vervielfältigung und Nutzung für den eigenen Zweck dieses Handbuches ist nicht gestattet Alle Rechte vorbehalten Seine auch auszugsweise Reproduktion ohne schriftliche Zustimmung der Neri SpA ist verboten Die Neri SpA beh...

Reviews: