background image

                       

                       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.4.2

 

Date

 

&

 

Time

 

Setting

The

 

Date

 

&

 

Time

 

settings

 

tab

 

(Figure

 

11)

 

is

 

used

 

to

 

set

 

the

 

date,

 

time,

 

and

 

time

 

zone.

 

BDG

256

 

supports

 

all

 

five

 

time

 

zone

 

of

 

North

 

America.

 

For

 

other

 

parts

 

of

 

the

 

world,

 

the

 

time

 

zone

 

“World”

 

may

 

be

 

chosen.

     

 
 
 
 
 
 
 
 

Figure

 

11

 

 

Date

 

&

 

Time

 

Setting

   

4.4.3

 

Communication

 

Address

 

Setting

 

The

 

communications

 

address

 

settings

 

tab

 

(Figure

 

12)

 

is

 

used

 

to

 

set

 

the

 

power

 

line

 

communication

 

address

 

of

 

the

 

micro

inverters

 

linked

 

to

 

the

 

device.

 

One

 

BDG

256

 

gateway

 

can

 

monitor

 

up

 

to

 

255

 

micro

 

inverters.

 

Inverter

0

 

on

 

the

 

address

 

list

 

corresponds

 

to

 

the

 

total

 

output

 

of

 

all

 

inverters

 

connected

 

to

 

the

 

gateway

 

Address

 

settings

 

can

 

be

 

input

 

using

 

either

 

the

 

small

 

input

 

panel

 

on

 

the

 

touch

screen

 

or

 

an

 

external

 

USB

 

keyboard.

 

The

 

communication

 

address

 

of

 

a

 

micro

 

inverter

 

consists

 

of

 

the

 

last

 

8

 

characters

 

(0~F)

 

on

 

the

 

BDM

 

micro

 

inverter

 

bar

 

code.

     

[need

 

a

 

bar

 

code

 

example]

 

 
 
 
 
 
 
 
 

Figure

 

12

 

Communication

 

Address

 

Setting

 

 
 

4.5

 

Backup/Clear

 

Data

 

When

 

a

 

USB

 

flash

 

disk

 

is

 

inserted,

 

press

 

the

 

Save/Clear

 

button

 

to

 

call

 

up

 

the

 

following

 

dialog

 

box

 

(see

 

Figure

 

13).

 

 

 
 
 
 
 
 

Figure

 

13

 

 

Backup/Clear

 

Data

   

Press

 

the

 

Save

 

button,

 

and

 

press

 

Yes

 

in

 

the

 

confirmation

 

window

 

that

 

appears

 

to

 

compress

 

and

 

backup

 

all

 

collected

 

data

 

to

 

the

 

USB

 

flash

 

disk.

 

The

 

document

 

will

 

automatically

 

use

 

the

 

backup

 

date

 

for

 

its

 

name.

 

Press

 

the

 

Reset

 

button,

 

and

 

press

 

Yes

 

in

 

the

 

confirmation

 

window

 

that

 

appears

 

to

 

clear

 

all

 

collected

 

data.

 

The

 

device

 

settings

 

will

 

not

 

be

 

changed.

 

4.6

 

Status

 

Bar

 

The

 

bottom

 

field

 

on

 

all

 

display

 

pages

 

consists

 

of

 

the

 

status

 

bar,

 

which

 

displays

 

the

 

device's

 

operating

 

status,

 

the

 

current

 

IP

 

address,

 

and

 

the

 

current

 

date

 

and

 

time.

 

“OK”

 

means

 

that

 

the

 

device

 

is

 

operating

 

normally.

 

A

 

16

bit

 

error

 

code

 

will

 

be

 

displayed

 

in

 

the

 

form

 

of

 

a

 

hex

 

number

 

if

 

there

 

happens

 

to

 

be

 

a

 

malfunction.

   

The

 

meaning

 

of

 

the

 

error

 

code

 

is

 

listed

 

in

 

the

 

following

 

table.

 

Error code 

Error 

Bit-0 

DC over voltage 

Bit-1 

DC under voltage 

Bit-2 hardware 

error 

Bit-3 

Inverter over voltage 

Bit-4 Frequency 

over 

Bit-5 Frequency 

under 

Bit-6 

AC voltage RMS over 

Bit-7 

AC voltage RMS under 

Bit-8 

Peak AC voltage over 

Bit-9 

AC current RMS over 

Bit-10 

Peak AC current over 

Bit-11 Temperature 

over 

Bit-12 ADC 

error 

Bit-13 

GFDI fault indicator 

Bit-14 

Relay error (for some model) 

Bit-15 

PLC Communication Error   

 

09

 

08

 

Summary of Contents for BDG?256

Page 1: ...5377 China Add No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 80934197 FAX 86 532 81100917 Email info northernep cn Web www northernep cn NEP Gateway BDG 256 Installation and Operation Manual N136 SAA 130307 ...

Page 2: ...ALLTION 4 USER INTERFACE 4 1 Main Interface 4 2Interface Overview 4 3 Energy functions 4 4 Setting 4 5 Backup Clear Data 4 6 Status Bar 5 WEB INTERFACE 5 1 Local web Page inside BDG 256 5 2 NEP Web Server 6 SPECIFICATION 7 WARRY AND PRODUCTION INFORMATION 01 02 02 02 02 03 04 05 05 05 06 07 08 09 10 10 11 11 12 ...

Page 3: ...this R D team and two core technical engineers with American PH D Degree worked in leading U S companies for more than 10 years separately in GE Global R D center and Motorola R D center and achieved more than 60 American patents NEP Company has a complete photovoltaic products series The photovoltaic inverter series of products including 180W 500W micro inverters 1 5kW 5kW single phase solar inve...

Page 4: ...NTS FOR ANY SERVICE WORK 2 FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor...

Page 5: ...s will read 0 at start up for the first time Figure 1 BDG 256 Main Display Figure 1 shows the BDG 256 main interface The main interface is arranged in three horizontal rows which consist of the tool bar at the very top the display area in the middle and the status bar at the lower part of the screen The tool bar contains 7 buttons Save Clear backup restore factory defaults Summary Display summary ...

Page 6: ...presents the amount of energy generated kWh on the day Figure 7 Last 7 Days Energy 4 3 3 Monthly Energy Pressing this button will bring up a bar chart showing power generation over each month for the last 12 months see Figure 8 This display is similar to the Last 7 Days Energy display The x axis represents months and the current month is on the last The y axis represents the amount of energy gener...

Page 7: ...see Figure 13 Figure 13 Backup Clear Data Press the Save button and press Yes in the confirmation window that appears to compress and backup all collected data to the USB flash disk The document will automatically use the backup date for its name Press the Reset button and press Yes in the confirmation window that appears to clear all collected data The device settings will not be changed 4 6 Stat...

Page 8: ... 256 Figure 14 Login Page Figure 15 Today s Output Page 5 2 NEP Web Server Figure 16 Monitoring Interface 6 SPECIFICATION Communications Interface Communication with Micro Inverter Power Line Communication Ethernet 10 100 auto sensing auto negotiation USB USB 2 0 interface auto sensing auto negotiation Monitoring capacity 255 micro inverters Human Interface Display LCD touch screen Power Requireme...

Page 9: ...subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the NEP product specifications including high input voltage from generators and lightning strikes 3 the product if repairs have been done to it other than by NEP or its authorized service centers hereafter ASCs 4 the product if it i...

Reviews: