7 Control panel settings B-Control
7.1
List of parameters
7.1.1
Information menu
Tab.5
Information list
Information
Description
Display
°C
Heating water temperature (°C)
The symbol
flashes
°C
Domestic hot water temperature (°C)
The symbol
flashes
If no domestic hot water sensor connected: dis
play — — —
°C
Outside temperature (°C)
The symbol
flashes.
Burner status
Energy meter on the heating water circuit
The symbol
flashes.
The displayed value flashes.
Energy meter on the domestic hot water circuit
The symbol
flashes.
The displayed value flashes.
Information on the boiler not available
For more information, see
Browsing in the menus, page 16
7.2
Setting the parameters
7.2.1
Setting the heating water temperature
No temperature sensor connected
Outside temperature sensor con
nected
Set the heating water temperature
setpoint
Set the required room temperature
1. Set the temperature setpoint or room temperature depending on the
configuration described above by turning the setting button
.
Note
If the heating water temperature setpoint is lower than 16°C and if
no outside temperature sensor is connected, the heating cuts out
automatically.
Note
This setting is possible regardless of the display.
2. Go back to the main display by pressing the key for two seconds.
Note
After five seconds without pressing any keys on the control panel,
the display goes back to the main display.
Fig.32
MW
-3
0
0
0
2
4
3
-2
Fig.33
MW
-3
0
0
0
2
4
4
-2
7 Control panel settings B-Control
22