Tab.13 List of sub-menus
Sub-menu
Description
CU-OH04 central unit PCB
HMI control panel
Tab.14 List of sub-menus for an installation with an additional PCB
Sub-menu
Description
CU-OH04 central unit PCB
SCB-04B additional PCB
HMI control panel
Tab.15 Values available (X) in sub-menus
,
,
Parameter
Description
Unit
CU-OH04
PCB
SCB-04B PCB
AM010
Pump rotation speed
%
X
AM012
Control system sequence: Status
Important
See following table
X
X
AM014
Control system sequence: Sub-Status
Important
See following table
X
X
AM016
Heating circuit flow temperature
°C
X
AM018
Heating circuit return temperature
°C
X
AM019
Heating circuit hydraulic pressure, in the heating system
bar
X
AM027
Outdoor temperature
°C
X
AM051
Generator relative output
%
X
AM091
Seasonal mode active (Summer/Winter)
X
X
AM101
Temperature set point
X
CM030
Room temperature measured
°C
X
X
CM040
Circuit flow temperature
°C
X
CM060
Pump speed
%
X
CM120
Circuit operating mode:
= AUTO
= manual
= frost protection
= temporary
X
X
CM130
Current activity status:
= frost protection
= reduced
= comfort
= anti-legionella
X
X
CM190
Desired room temperature set point
°C
X
X
CM210
Temperature outside the zone
X
X
DM001
Domestic hot water tank temperature
°C
X
X
PM002
Heating temperature set point
°C
X
FXX.XX
Software version for the selected PCB
X
X
PXX.XX
Parameter version for the selected PCB
X
X
8 Control panel settings IniControl 2
32