Important
AP : Appliance Parameters = Appliance parameters
Tab.9
List of parameters in the
/
sub-menus of the User menu
Parameter
Description
CU-OH04 factory
setting
Factory setting
SCB-04B
AP016
Central heating operation:
= off (no heating or cooling)
= on
1
not available
AP017
Domestic hot water tank operation:
= off
= on
1
not available
AP073
SUMMER / WINTER set point switch:
Can be set from 15 to 30°C
set to 30.5°C = function deactivated
22°C
only accessible
to the installer
AP074
SUMMER override:
= off
= on
0
0
AP082
Changing the summer/winter timer
:
= off
= on
1
not available
For more information, see
Browsing in the menus, page 19
Selecting a PCB, page 20
8.1.2
COUNTERS /TIME PROG / CLOCK menus
Tab.10 List of sub-menus
Sub-menu
Description
COUNTERS
(1)
Timer programming for the main heating circuit
(1)
Timer programming for the additional heating circuit B
Timer programming for the domestic hot water circuit
Setting the clock and the date
(1) This menu is not displayed if a room sensor is connected.
For more information, see
Browsing in the menus, page 19
Selecting a PCB, page 20
8 Control panel settings IniControl 2
7719764 - v02 - 16112018
EFU-S
27