5 Utilisation with the control panel B-Control
5.1
Browsing in the menus
Press any key to turn on the backlight for the control panel screen.
Important
If no key is pressed within 3 minutes, the control panel backlight
will go out.
The key is used to access the various menus:
Tab.3
Menus available
Information menu
Chimney Sweep menu
Press the key to access the Information menu.
Press the key for 2 seconds to go back to the main display.
Press the key for 2 seconds to access the Chimney Sweep menu.
Press the key for 2 seconds to go back to the main display.
Keep pressing the key to scroll through the information.
Important
Information menu: 5 minutes after the key is pressed for the
last time, the display goes back to the main display.
Chimney Sweep menu: Thirty minutes after the key is
pressed for the last time, the display goes back to the main
display.
5.2
Start-up
If the boiler was powered off:
1. Check that the heating system and the boiler are adequately primed
with water. Recommended pressure between 0.15 and 0.2 MPa (1.5
and 2.0 bar).
2. Check that the storage tank is filled with fuel.
3. Open the oil inlet valve.
4. Switch on the boiler.
A venting cycle is run automatically.
The display shows the operating status of the boiler, the heating flow
temperature and any error codes.
Fig.15
MW-1000668-1
Fig.16
MW-1000667-1
2’’
Fig.17
MW-1000668-1
5 Utilisation with the control panel B-Control
7719764 - v02 - 16112018
EFU-S
17