Nuvo-7160GC/ Nuvo-7164GC Series
157
Appendix B PoE On/ Off Control
The system offers 802.3at PoE+ ports and users are allowed to manually turn on or off the
power supply of each PoE port. This can be useful in power device (PD) fault-recovery or
power reset. The APIs are part of Neousys WDT_DIO driver package. Please follow the
instructions in
Appendix AWatchdog Timer & Isolated DIO
for installation before programming
PoE on/off control function.
GetStatusPoEPort
Syntax
BYTE GetStatusPoEPort (Byte port);
Description
Get current on/off status of designated PoE port.
Parameter
port
BYTE value specifies the index of PoE port. Please refer to the
following illustration,
port
should be a value of 1 ~ 4
Return Value
BYTE value indicating PoE on/off status
0 if port is disabled (off)
1 if port is enabled (on)
Usage
BYTE bEnabled = GetStatusPoEPort (1); //Get on/off status of PoE
Port#1
PoE+ ports on the front panel
Summary of Contents for Nuvo-7160GC Series
Page 1: ...Neousys Technology Inc Nuvo 7160GC Series Nuvo 7164GC Series User Manual Revision 1 0...
Page 17: ...Nuvo 7160GC Nuvo 7164GC Series 17 1 2 3 Nuvo 7160GC Top View...
Page 18: ...Nuvo 7160GC Nuvo 7164GC Series 18 1 2 4 Nuvo 7160GC Bottom View...
Page 20: ...Nuvo 7160GC Nuvo 7164GC Series 20 1 3 3 Nuvo 7164GC Top View...
Page 21: ...Nuvo 7160GC Nuvo 7164GC Series 21 1 3 4 Nuvo 7164GC Bottom View...
Page 84: ...Nuvo 7160GC Nuvo 7164GC Series 84 4 Remove the Cassette module cover and bezel cover s...
Page 146: ...Nuvo 7160GC Nuvo 7164GC Series 146 7 Follow the 6 step setup procedure as instructed...
Page 148: ...Nuvo 7160GC Nuvo 7164GC Series 148 9 When done click on Finish and restart the system...