2
Registered trademarks - All rights reserved
NEOMITIS
®
LIMITED - 4th Floor, Lincoln House, 300 High Holborn, London WC1V 7JH
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: [email protected]
Creating innovative solutions for ambient comfort
www.neomitis.com
FACTORY SETTINGS
Note: To restore factory settings, press and hold down this part for more
than 3 seconds using the tip of a pen.
All LCD display will be turned ON for 2
seconds and the factory settings will be
restored.
C
C
Settings
Factory settings
Set temperature
20°C
The boiler is not heating:
- Check that the thermostat is calling for heat if yes then the thermostat
would appear to be working check that the boiler has not switched itself
off.
If no increase set temperature.
- Check the position of the batteries. Remove them for 30 seconds and
reinsert them. If the problem persists, replace the 2 batteries.
Nothing in the display:
- Check the position of the batteries. Remove them for 30 seconds and
TROUBLESHOOTING
Note: the receiver is usually located near your boiler.
4-
Thermostat RF icon and re-
ceiver green light will be solid
when pairing is complete.
3-
Thermostat RF icon and recei-
ver green light are blinking.
Override
RF Test
... an explanation for householders
A room thermostat simply switches
the heating system on and off as
necessary. It works by sensing the
air temperature, switching on the
heating when the air temperature
falls below the thermostat setting,
and switching it off once this set
temperature has been reached.
Turning a room thermostat to a hi-
gher setting will not make the room
heat up any faster. How quickly the room heats up depends on the de
-
sign of the heating system, for example, the size of boiler and radiators.
Neither does the setting affect how quickly the room cools down.
Turning a room thermostat to a lower setting will result in the room being
controlled at a lower temperature, and saves energy.
The heating system will not work if a time switch or programmer has swit
-
ched it off. The way to set and use your room thermostat is to find the
lowest temperature setting that you are comfortable with, and then leave
it alone to do its job. The best way to do this is to set the room thermostat
to a low temperature – say 18ºC – and then turn it up by one degree each
day until you are comfortable with the temperature. You won’t have to
adjust the thermostat further. Any adjustment above this setting will waste
energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only
one room thermostat to control the whole house. But you can have diffe
-
rent temperatures in individual rooms by installing thermostatic radiator
valves (TRVs) on individual radiators. If you don’t have TRVs, you should
choose a temperature that is reasonable for the whole house. If you do
have TRVs, you can choose a slightly higher setting to make sure that
even the coldest room is comfortable, then prevent any overheating in
other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense the temperature, so
they must not be covered by curtains or blocked by furniture. Nearby
electric fires, televisions, wall or table lamps may prevent the thermostat
from working properly.
WHAT IS A ROOM THERMOSTAT
Please refer to the installing instructions for any informations about batte
-
ries life, standards and product environment.
TECHNICAL SPECIFICATIONS
The desired temperature can be set.
1-
To set the temperature, turn the dial clockwise, to increment the tem
-
perature, turn the dial counter-clockwise, to decrement the tempera
-
ture.
The default temperature is 20°C (68°F).
TEMPERATURES SETTING
OPERATING
C
C
Override
RF Test
reinsert them. If the problem persists, replace the 2 batteries.
The room temperature is not high enough, the boiler is not providing
enough heat:
- Check the active desired temperature and increase it if need be
(see
page 1)
.
You made a mistake while setting:
- You just need to restore factory settings, as explained in the “Factory
settings” section
(see page 2)
. This will reverse any changes you might
have made.
The system is not heating but is on:
- If
and indicator light is on but the system remains cold, then you should
contact your installer.
If the problem persists, then contact your installer.