background image

OWNER'S MANUAL

              P/N P474-0130

Use with most Air Conditioning & Heating Systems including: 1 Stage

Electric Cooling & Gas Heating, Heat Pump, Electric Heat, Hydronic Heat,

Fan Coils and PTAC units.. 

Non-Programmable

Digital Thermostat 

TOTALINE

Star

72

TOTALINE

Replacement Components Division - Carrier Corporation - Made in China     

Millivolt Compatible
Battery Operated 
Digital Display

DC Voltage Compatible
Stages: 1-Heat, 1-Cool
Easy Operation

Summary of Contents for P474-0130

Page 1: ...as Heating Heat Pump Electric Heat Hydronic Heat Fan Coils and PTAC units Non Programmable Digital Thermostat TOTALINE Star 72 TOTALINE Replacement Components Division Carrier Corporation Made in China Millivolt Compatible Battery Operated Digital Display DC Voltage Compatible Stages 1 Heat 1 Cool Easy Operation ...

Page 2: ... Page 2 Contents Page Page 2 Remove Old Thermostat Safety Warnings Location of Controls Display Normal Operation Preparation Installation Battery Replacement Wire Connections Jumper Configuration Test Operation Troubleshooting Warranty ...

Page 3: ...ced immediately The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced The annual battery replacement is especially critical in locations subject to freezing temperatures The thermostat will be unable to turn on the Heat if the batteries are exhausted Page 3 Replacement Components Division Carrier Corporation Patents Pending Safety ...

Page 4: ...OWNER S MANUAL DIGITAL THERMOSTAT Page 4 Location of Controls MODE SWITCH Heat Cool or Off On or Auto FAN SWITCH UP DOWN BUTTONS 72 TOTALINE TEMPERATURE DISPLAY ...

Page 5: ...n arrow buttons are pressed the thermostat will show the desired Set Temp temperature indicator Once this screen is reached you may use the Up or Down arrow buttons to adjust the desired room temperature After five seconds with no button presses the thermostat will revert back to show the current room temperature ...

Page 6: ...o the fan will turn on only with a heat or cool demand When Fan On is selected the fan will run continuously even when the mode switch is set to Off Adjust the desired set temperature with the Up or Down buttons OWNER S MANUAL DIGITAL THERMOSTAT Page 6 MODE SWITCH Heat Cool or Off On or Auto FAN SWITCH UP DOWN BUTTONS 72 TOTALINE ...

Page 7: ...g system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Proper installation of the thermostat will be accomplished by following these step by step instructions If you are unsure about any of these steps call a qualified technician for assistance Step 1 Preparation 72 TOTALINE Heat Off Cool FanOn FanAuto 72 TOTALINE Heat Off Cool FanOn...

Page 8: ...s as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat Keep the old thermostat for reference purposes until your new thermostat is functioning properly Page 8 INSTALLATION INSTRUCTIONS Step 2 Remove Replace Old Thermostat 72 TOTALINE Heat Off Cool FanOn FanAuto 72 TOTALINE Heat Off Cool FanOn FanAuto 72 TOTALINE Heat Off Cool FanOn FanAut...

Page 9: ...procedure in the other screw driver slot Separate the housing halves by pulling the top forward until the pins release and then lift the bottom out To pull the housing apart insert a small blade screw driver into the slot and rotate 90 This will release the top housing snaps SCREWDRIVER SLOTS The batteries must be replaced immediately when the thermostat displays the Low Battery code fig 1 FIG 1 ...

Page 10: ...NCE EVERY YEAR OR WHEN THE LOW BATTERY ICON APPEARS pages 3 9 USE AA SIZE ALKALINE BATTERIES USE AA SIZE ALKALINE BATTERIES POSITION BATTERIES AS SHOWN FAN W HEAT HEAT PUMP 1 2 3 1 2 3 J1 J2 INSTALLATION INSTRUCTIONS Page 10 Battery Replacement ...

Page 11: ...Energize to Heat 72 TOTALINE Heat Off Cool FanOn FanAuto W1 W or H Heating W G or F Fan G O Rev Valve Energize to Cool O A label is provided on the backplate that prevents drafts originating inside the wall from entering the thermostat These drafts left unchecked may cause incorrect room temperature readings Please do not remove this label from the thermostat Insert the wires through the slots pro...

Page 12: ...at Page 12 FAN COMPRESSOR POWER W G R Y W Y B O G R 4 Wire 1 Stage Cooling 1 Stage Gas Heat Residential Gas or Electric Heat Electric Cool split systems package units GAS OR ELECTRIC HEAT 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment ...

Page 13: ...4 Wire 1 Stage Cooling 1 Stage Heat Heat Pump with O reversing valve Residential Heat Pumps split systems package units with no auxiliary heat FAN POWER G R COMPRESSOR Y W Y B O G R REVERSING VALVE O 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment ...

Page 14: ...4 Wire 1 Stage Cooling 1 Stage Heat Heat Pump with B reversing valve Residential Heat Pumps split systems package units with no auxiliary heat FAN POWER G R COMPRESSOR Y W Y B O G R REVERSING VALVE B 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment ...

Page 15: ...Gas or Electric Heat Page 15 FAN POWER G R W W Y B O G R 3 Wire 1 Stage Heat Residential Gas or Electric Heat units with a separately controlled fan GAS OR ELECTRIC HEAT 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment ...

Page 16: ...ple Wiring Diagrams Gas or Electric Heat Page 16 POWER W R W Y B O G R 2 Wire 1 Stage Gas Heat Residential Gas or Millivolt units GAS OR ELECTRIC HEAT 2 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment ...

Page 17: ...S Sample Wiring Diagrams Gas or Electric Heat Page 17 FAN POWER G R Y W Y B O G R 3 Wire 1 Stage Cooling Residential Electric Cool units COOLING 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment ...

Page 18: ...ther applications this jumper should remain set to the OFF position If the HVAC unit is a Heat Pump then jumper should be set to ON For all other applic ations this jumper should remain set to the OFF position 72 TOTALINE Heat Off Cool FanOn FanAuto 72 TOTALINE Heat Off Cool FanOn FanAuto REPLACE WITH ALKALINE BATTERIES ONCE EVERY YEAR USE AA SIZE ALKALINE BATTERIES FAN W HEAT 1 2 3 ON OFF 1 2 3 H...

Page 19: ...rmostat Press the Up or Down buttons until the set temperature is 10 degrees below room temperature The HVAC unit should energize in the cooling mode pages 5 6 Turn on the power to the Heating Air Conditioning system Adjust the Slide Switch until it is located under the word OFF Adjust the other slide switch until it is located under the word Fan On The fan should turn on and run continuously page...

Page 20: ...int and to correct the Mode Switch position or replace the batteries page 10 INSTALLATION INSTRUCTIONS Page 20 Trouble Shooting 72 TOTALINE Heat Off Cool FanOn FanAuto SYMPTOM The slide switches on the thermostat are very difficult to move CAUSE The backplate of the thermostat is deformed by being screwed tightly into a wall that is not perfectly flat REMEDY Loosen the screws holding the thermosta...

Page 21: ...EDY Consult the Normal Operation section in this manuals to raise the heating setpoint and to correct the Mode Switch position page 10 or replace the batteries INSTALLATION INSTRUCTIONS Page 21 Trouble Shooting 72 TOTALINE Heat Off Cool FanOn FanAuto P N 88 396 Rev 2 C c F FOR HOME OR OFFICE USE Tested to Comply with FCC Standards Battery Stat P N P474 0130 4Z95 ...

Page 22: ... THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR 1 Normal maintenance as outlined in the installation and servicing instructions or owners manual including filter cleaning and or replacement and lu...

Reviews: