OOO Neomatica. Terminal ADM007 GLONASS / GPS. Rev.1.3 dated 13.09.2019
19
GPRS:
APN=internet.mts.ru,
user=mts, pass=mts
Z
– password, default
Z=beeline.
10
SETHOST0 X,Y
Example:
SETHOST0
134,236,21,2,12300
HOST0=X,Y
Example:
HOST0=134.236.21.2:1230
0
X - IP adress,
Y - server port.
Five numbers separated
by commas.
Configuring the IP address and port of the server to
which the tracker connects to transmit information. A
command without parameters returns the current server
address and port.
11
DN0 X:Y
Example:
DN0 www.test.ru:1000
HOST0=X:Y
Example:
HOST0= www.test.ru:1000
X - domain name of the
server,
Y - server port.
Configure the domain name and port of the server to
which the tracker connects to transmit information. A
command without parameters returns the current server
address and port.
12
ERASE FLASH
ERASE FLASH
Command without
parameters.
Erase all information packets stored in memory. After
executing this command, the current information packet
number is reset, the tracker is rebooted.
13
ERASE EEPROM
ERASE EEPROM
Command without
parameters.
Restore the tracker's factory settings and restart the
tracker.
14
PERIOD X,Y
Example:
PERIOD 20,120
PERIOD min=X, max=Y
Example:
PERIOD min=20, max=120
X
– the recording period
during the movement in
seconds,default X=30.
Y
– the recording period
during parking in
seconds, by default
Y=300.The value of X
must be less than Y.
Set the recording period in the memory of information
packets
during
driving
and
parking.
A command without parameters returns the current
settings.
15
TRACKSET X
The response displays
a
detailed
configuration of all set
parameters
of
the
travel path
X= 0…4
Select the preset of the travel path drawing
quality. More details see in clause 5.5.1
Selecting presets of route drawing quality
16
InTrue X,Ymin,Ymax
Example:
InTrue 0,10000,60000
InTrue X,Ymin,Ymax
Example:
InTrue 0,10000,60000
X=0
– input number
(always 0);
Ymin
– minimum range
limit in mV;
Ymax=60000
– the
maximum range limit in
mV (unchanged value).
Set the voltage range of the logical unit on the analog
input.
17
InFalse X,Ymin,Ymax
Example:
InFalse 0,0,4000
InFalse X,Ymin,Ymax
Example:
InFalse 0,0,4000
X=0
– input number
(always 0). Ymin
–
minimum range limit in
mV; Ymax
– maximum
range limit in mV.
Set the voltage range of logical zero on the analog input.
18
InInfo X
Example:
InInfo 0
Example: Input 0: InTrue
8000..15000,
InFalse
0..3000
X=0
– input number
(always 0).
Request information about the input settings.
19
INPUT
INPUT0 = 12000
Command without
parameters.
Query the current measured voltage level at the analog
input (mV).