Running Quick Tests

The quick test option can be used anytime to take a test not associated with a site in the master site plan. This 
can be especially useful during training or demos when a site plan is not needed. To run a quick test, select 
the quick test option on the home screen, and insert the sampler to run the test. Quick tests can also be run 
at any time by inserting a sampler while on the home screen provided that function has been enabled in the 
settings menu. If the option is selected in the settings menu, running from the home page will use the last 
used site and will not initiate a quick test. Selecting quick test will always use the quick test site. A progress 
indicator will appear, displaying the progress of the sample. Once complete, the results screen will appear.

Results Screen

• Plan – ---

• Area – --- 

• Group – ---

• Site – <Quick Test>

• User 

• Date/Time 

• Result 

• RLU 

Add Notes

To add notes to the result, select notes* on screen. Type in the note and click the right arrow button to confirm 

the note. Notes will be in the comments field when results are imported into the data manager software.

Retest

To run a retest, select the retest button on the results screen, insert the sample, and run the test. This test will 

be designated as a retest result when results are imported into the data manager software.

Preparing the Instrument for Use

Summary of Contents for AccuPoint Advanced Next Generation

Page 1: ...AccuPoint Advanced Next Generation User Guide...

Page 2: ...of the Instrument 06 Cleaning the Instrument Chapter 4 Preparing the Instrument for Use 07 Power 08 Home Page 09 Running Quick Tests 09 Results Screen 09 Add Notes 09 Retest 10 Sample Procedure Chapt...

Page 3: ...ager Software 20 Sampler Type Surface Liquid or Alkaline Phosphatase 20 Setting the Pass Marginal and Fail Thresholds 21 Troubleshooting Chapter 11 Technical Information 25 Electromagnetic Compatibili...

Page 4: ...t of providing greater sensitivity through a clearer distinction between very low levels of ATP The AccuPoint Advanced NG instrument offers enhanced navigation touch screen wireless data transfer capa...

Page 5: ...a food debris yeast and mold Bioluminescence is a chemical reaction that produces light ATP bioluminescence occurs when ATP from a sample comes into contact with luciferase an enzyme found in fireflie...

Page 6: ...NEOGEN com 4 Eject button Full color touch screen display USB data and charging port RFID antenna Sampler compartment On Off and navigation d pad Operating Principles and Technology...

Page 7: ...esting liquids Be sure to remove and properly dispose of samplers after each reading from the instrument The sampler reagents and their cartridges are non toxic and may be disposed of without any spec...

Page 8: ...at may be contaminated To clean the lens use the AccuPoint Advanced NG cleaning swab moistened with a solution of isopropyl alcohol 70 Be sure to turn the instrument upside down while cleaning the len...

Page 9: ...too low a notification will appear recommending you charge the instrument immediately Once the battery level reaches a critically low state a notification will appear warning that the instrument is p...

Page 10: ...e AccuPoint Advanced NG instrument connects to the data manager software on your PC Battery Icon indicates the amount of battery life left on the instrument Menu Navigation menu with sites results set...

Page 11: ...the last used site and will not initiate a quick test Selecting quick test will always use the quick test site A progress indicator will appear displaying the progress of the sample Once complete the...

Page 12: ...ampling Under standard testing select the correct site to be tested 03 Sample your site by drawing a 4 x 4 in 10cm x 10cm square With a vertical and horizontal back and forth motion fill in the square...

Page 13: ...e sampler and begin test Note keep instrument upright while the sample is being read 08 The RLU value will display along with a symbol for pass marginal or fail 09 On the results screen users have the...

Page 14: ...ny tests taken in that session To log in select the username field Navigate to the appropriate username in the list by scrolling with the up and down buttons on the d pad or use the search field on th...

Page 15: ...thout the use of a plan subset proceed to area selection To run a standard test as a part of a plan subset select select plan Navigate to the appropriate plan in the plans list by scrolling with the u...

Page 16: ...ure can be used to avoid confusion and save time by automatically pulling up the appropriate group based on the location of a physical RFID tag See the RFID section for more information RFID tags are...

Page 17: ...tton to confirm the added note Notes will be stored in the comments field when results are imported into the data manager software Retest To run a retest of the same site remove sample and select the...

Page 18: ...ll dim when the instrument is idle Off Timeout Adjusts the amount of time before the instrument automatically powers off when the instrument is idle Auto Select Site Automatically selects the next sit...

Page 19: ...data transfer to occur A Wi Fi icon with a lock will appear when the instrument is connected to Wi Fi and ready to transfer To sync results select sync results to transfer test results wirelessly to...

Page 20: ...rate when it recognizes the RFID tag A green check mark will appear next to groups which have RFID tags assigned Be sure to note on the RFID sign which group has been associated with it This will help...

Page 21: ...munication the sync results button can be used to send new readings data to the active data manager database When the sync results button is pressed the device will attempt to re establish a secure co...

Page 22: ...two sampling modes surface and liquid Both the AccuPoint surface and access samplers are designed to be read in surface mode The AccuPoint liquid sampler is read in liquid mode A water droplet symbol...

Page 23: ...NEOGEN com 21 Troubleshooting Error 01 Door open during unit initialization while powering on Error 02 Try to run test when unit is being charged Additional Features...

Page 24: ...NEOGEN com 22 Error 03 Reminder to remove used sampler after testing is complete Error 04 Please wait baseline in progress Additional Features...

Page 25: ...NEOGEN com 23 Error 05 Leaving the door open when the unit is trying to take a baseline reading Error 06 The unit battery is low charge unit soon by connecting to the USB charger Additional Features...

Page 26: ...07 The unit battery is depleted the unit is shutting down Connect the unit to the USB charger Error 08 Tilt warning flag unit was not kept upright during the test Test results are marked with this fla...

Page 27: ...andard s Operationissubjecttothefollowingtwoconditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation...

Page 28: ...this product There is no warranty of merchantability of this product or the fitness of the product for any purpose NEOGEN shall not be liable for any damages including special or consequential damage...

Page 29: ...NEOGEN Corporation 2021 NEOGEN and AccuPoint are registered trademarks of NEOGEN corporation Lansing MI 48912 U S NEOGEN com...

Reviews: