27
4.4 Short Tape Feeder
1. There is a needle in front of Strip feeder tray, but the hole of the strip into the
needle, the components will be in the same position after change new strip.
2. Tear the strip film carefully.
3. The pick height of the strip is very important, have to set the pick height just above
the surface of the component, if it is too low, will bring vibration to the following
component. How to get the correct height: go to Manual setting page, move the nozzle
to the pick-up position, drop the nozzle to the surface of the component and record the
drop distance. For example, if the drop distance is 20.5mm, and the Nozzle Height
Datum is 20.0mm in the setting, then you need to set pick height of this component to
-0.5mm.
4. Strip feeder Tray is Flexible Feeder, set columns to 1, rows number is the number
of components, set the correct Pitch.