Kg
mm
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
OPERATING TEMPERATURE
OPERATING HUMIDITY
STORAGE TEMPERATURE
STORAGE HUMIDITY
VIBRATION (*9)
SHOCK
WEIGHT
SIZE (WxHxD)
OUTPUT ON/OFF
OUTPUT GOOD
OUTPUT VOLTAGE PROGR.
OUTPUT CURRENT PROGR.
REMOTE SENSING
COMMUNICATION INTERFACE
ENVIRON-
MENT
MECHANI-
CAL
EXTERNAL
FUNCTIONS
SAFETY STANDARDS
EMC STANDARDS
APPROVALS
NOTES:
* 1 MINIMUM VOLTAGE IS GUARANTEED TO MAXIMUM 0.2% OF THE RATED OUTPUT VOLTAGE.
* 2 MINIMUM CURRENT IS GUARANTEED TO MAXIMUM 0.4% OF THE RATED OUTPUT CURRENT.
* 3 GIVEN FOR CONTROL OF THE OUTPUT VIA THE SERIAL COMMUNICATION OR VIA FRONT PANEL CONTROLS.
* 4 TIME FOR RECOVERY TO /- 50mV AGAINST CURRENT CHANGE OF 50% TO 100%.
* 5 INVERTER SHUT DOWN METHOD, MANUAL RESET BY AC INPUT RECYCLING.(OVP WILL SHUT DOWN OUTPUT).
* 6 AT 100V/200V AND MAXIMUM OUTPUT POWER.
* 7 FOR 200W UNITS - AT COLD START Ta = 25
O
C.
* 8 FOR CASES WHERE CONFORMANCE TO VARIOUS SAFETY SPECS, (UL, IEC ETC.) ARE REQUIRED TO BE DESCRIBED
AS 100-240VAC (50/60Hz) ON NAME PLATE.
* 9 WHEN MOUNTED WITH MOUNTING SCREWS.
CONDUCTED EMI
RADIATED EMI
SERIAL OPERATION
PARALLEL OPERATION
COOLING
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ZUP60-
7
3.2
3.2
3.2
3.2
3.2
ZUP60-
3.5
2.9
2.9
2.9
2.9
2.9
ZUP36-
12
ZUP36-
6
ZUP20-
20
ZUP20-
10
ZUP10-
40
ZUP10-
20
ZUP6-
66
0 ~ 50
C: 100% Load.
O
-20 ~ 70
C
O
30 ~ 90% RH ( No Dewdrop )
10 ~ 95% RH ( No Dewdrop )
Less than 20G
10 ~ 55Hz, Amplitude (sweep 1min) Less than 2G, X,Y, Z, 1 hour each.
70 x 124 x 350.
By TTL Signal or Dry Contact - refer to instruction manual
Open collector - refer to instruction manual
By Voltage ( 0 ~ 4V ) or by Resistance ( 0 ~ 4K ) refer to instruction manual
By Voltage ( 0 ~ 4V ) or by Resistance ( 0 ~ 4K ) refer to instruction manual
Possible, maximum 0.5V drop on each load wire
RS232 and RS485 Built-in, IEEE488 Optional
UL 3111-1, EN61010-1
EN 61326-1, IEC 61326 -1, FCC part 15 (class A)
Master - slave method: up to 5 units, refer to instruction manual
Up to 2 units, refer to instruction manual
More than 100MOhm at 25
C and 70% R.H.
O
EN55022-B, FCC-B, VCCI-2
Forced air by blower fan, (blower fan is mounted within unit)
EN55022-A, FCC-A, VCCI-1
Input-Chassis: 2.0kVAC 1 min. Input-Output: 3.0kVAC 1 min. Output-Chassis: 500VAC 1min.
ZUP6-
33
2.1 SPECIFICATIONS: 200W/400W Series continued
8