The RS232 interface is accessible through the rear panel IN/OUT jacks. The jacks are 8 contacts each
and conform to EIA/TIA-568A requirements. The IN and OUT jacks are used to connect the units in a
RS232 or RS485 chain to a controller. The data format is ASCII, 8 bits/character no parity bit, one stop
bit. The baud rate can be selected to one of the 6 possible rates between 300 and 9600bps (refer to par.
5.2.3). Refer to par. 5.6 for detailed explanation.
Up to 31 ZUP units can be connected to the RS232 control as shown in Fig. 5-1.
5.3 REMOTE PROGRAMMING VIA RS232
5.3.1 Introduction
5.3.2 Rear panel connectors pinout
IN
RXD+
RXD+
TXD
+
TXD
+
RXD
_
RXD
_
TXD
_
TXD
_
Not used
Shield (connector enclosure)
Not used
RX (RS232)
NC
TX (RS232)
NC
SG
SG
OUT
Fig. 5-1: Linking ZUP units with RS232 control.
Fig. 5-2:
Rear panel connector pinout
(ZUP rear panel view)
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
NOTE
Tx and Rx are used for RS232 communication. Txd +/- and Rxd +/- are used for RS485
communication. Refer to RS232 and RS485 cables description for connection details.
ZUP (1)
ZUP (2)
ZUP (31)
RS232
1000m max.
RS485
RS485
10m max.
39