OPERATION
Testing
Test the unit to ensure proper operation by pressing the test button, this will sound the alarm if
the electronic circuitry, horn, and battery are working.
If no alarm sounds, there is a defective battery or other failure, you can refer to
“Trouble shooting” section for solution.
DO NOT
use an open flame to test your alarm, you could
damage the alarm or ignite combustible materials and start a fire.
LED indicators
Red LED-Flashing once every 40 seconds: indicates that the smoke alarm device is
operating properly
Red LED-Flashing:
When the test button is pressed, or when the smoke alarm device sense particles of
combustion and goes into alarm (constant pulsating sound), the red LED will flash once per
second.
The flashing LED and pulsating alarm will continue until the air is cleared or release test
button.
Red LED-Alarm silencer (Hush mode) indication: The red LED will flash once every
8 seconds, indicating the smoke alarm device is in the alarm silence (Hush) mode.
Low battery indication:
An intermittent “chirp” with red LED flashes once every 40 seconds: indicates that the
smoke alarm device is low battery, you may press the test button for pause alarm for
10 hours, but it will reset automatically after 10 hours.
Fault indication :
The alarm chirp occurs every 40 seconds.
NOTE:
When the units chirp once every 40 seconds, you can press the test button temporarily for
pausing this warning tone for 10 hours, it can still normally detect smoke during this period,
it only removes nuisance warning tone.
You can refer to “Trouble shooting” for solution, if there are still failures,
you MUST replace
it with a new alarm at once
or contact you retailer during warranty.
CAUTION
Due to the loudness (85 decibels) of the alarm.
Always stand an arms-length away from the unit when testing.
Test the alarm weekly to ensure proper operation.
Erratic or low sound coming from your alarm may indicate a defective alarm,
you can refer to “Trouble shooting” section for solution.
NOTE: WEEKLY TESTING IS REQUIERED.
EN
Summary of Contents for FL10-VdS
Page 11: ...11 Version 2 0 14 07 2016 EN Diagram 5 Diagram 6 Diagram 4 ...
Page 13: ...13 Version 2 0 14 07 2016 EN ĞĐůĂƌĞĚ ƉĞƌĨŽƌŵĂŶĐĞ E ϭϰϲϬϰ ϮϬϬϱ ϮϬϬϴ ʹ ŵŽŬĞ ĂůĂƌŵ ĚĞǀŝĐĞƐ ...
Page 14: ...14 Version 2 0 14 07 2016 EN ...
Page 26: ...26 Version 2 0 14 07 2016 DE Abbildung 4 Abbildung 5 Abbildung 6 ...
Page 28: ...28 Version 2 0 14 07 2016 DE ...
Page 42: ...42 Version 2 0 14 07 2016 FR ...
Page 56: ...56 Version 2 0 14 07 2016 IT ...
Page 70: ...70 Version 2 0 14 07 2016 ES ...