background image

NELSON

 HEAT TRACING SYSTEMS

  

INSTALLATION 

PLT-BC

 STANDARD POWER CONNECTION KIT

 

INSTRUCTIONS 

 

FOR ALL NELSON LT, CLT & HLT PRODUCTS 

(See sheet 6 for an alternate stripping method for HLT products.)

 

 

 

 

 

102mm (4")

 

 

 

  Lightly cut around cable outer jacket 102mm (4") 

from the end. Bend cable to break outer jacket. 

  Starting at the end, pull each bus wire away from  

the core material. 

  Lightly cut the outer jacket up the center between 

the first cut mark & the cable end. Bend cable to 
break outer jacket. 

  Remove exposed core material. 

 

 

 

 

Cut 6mm (0.25") off the end of each bus wire. 

 

 

 Proceed to 

“Power Termination”

 on sheet 7. 

  Remove the jacket from the heater cable. 

 

 

 

 

P.O. BOX 726                TULSA, OK  74101             TEL 918-627-5530            FAX 918-641-7336              www.nelsonheaters.com 

GA-1859 Rev. 6 

Sheet 5 of 8 

October 2006 

!

DO NOT CUT BUS WIRES 

WARNING:

 

 

  Shave the core material from the outside of each  

bus wire. 

Summary of Contents for PLT-BC

Page 1: ...al Conduit Drain Ground Locknut Flex Conduit ITEMS NOT INCLUDED IN KIT Stand off J Grommet Overjacket Products B Grommet Base Products U Grommet Double Entry or non standard construction Sealing Gromm...

Page 2: ...off Place stand off on pipe and fasten with pipe clamps included Slide the sealing grommet over the heater cable and position inside stand off opening For Braided CB Products only See Sealing Grommet...

Page 3: ...off opening Cut and remove the exposed heater cable Continue with step 5 on sheet 2 BRAIDED CB PRODUCTS 127mm 5 Bend heater cable and work it through the braid opening 114mm 4 5 Secure heater cable br...

Page 4: ...jacket 127mm 5 from the end Bend cable to break overjacket Lightly cut overjacket up the center between first cut mark and the cable end Bend cable to break overjacket Remove overjacket from heater ca...

Page 5: ...h bus wire away from the core material Lightly cut the outer jacket up the center between the first cut mark the cable end Bend cable to break outer jacket Remove exposed core material Cut 6mm 0 25 of...

Page 6: ...he core material Lightly cut the outer jacket up the center between the first cut mark the cable end Bend cable to break outer jacket Remove the exposed core material Remove the jacket from the heater...

Page 7: ...L apply silicone here Fiberglass Tape not included in kit Squeeze end seal and fill with silicone Push end seal over the heater cable Overjacket J or JT Products only Braided CB Products only The end...

Page 8: ...conduit locknut Connect bus wires power wires and ground braid to the terminal block See diagram above For Overjacket J or JT Products only Apply silicone at point braid leaves the overjacket Push al...

Reviews: