
Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
86
F
code
Description
Possible Values
Default
Unit
Notes
F58 Keep Gun Lift En-
able
OFF ON
OFF
X
Keeps the lifted after the weld for 5 se- conds for the purpose of
troubleshoo- ting applications.
F59 Pilot Delay
0 to 10
0
ms
Delay from the time the gun coil is en- ergized to the time the pilot arc is
tur- ned on.
F60 Constant Energy
Enable
OFF ON
OFF
X
Enable this to deliver constant energy to a weld referenced by a target
weld (stored as a preset).
F61
Pulse Cleaning
Contaminant to be
cleaned
Zinc or Galva- nized
to Primer Paint, Oil
or Oxide
Primer
Paint
X
Use this function to designate how the pulse cleaning function
determines ab- orts pulsing and begins the main arc. Select
‘Zinc\Galvanized’ to start the main arc when sensed voltage is above the
threshold set in F38
F62 Gun as Remote
OFF ON
OFF
X
Enable this to make the gun select pre- sets based on the gun trigger as
an in- put. Press and hold the gun trigger 2 seconds beyond the lift
check to incre- ment presets within bank.
F63 Pecker Mode
0 to 20
0
Number
of
Pecks
Increase the number of pecks to per- form a series of lift plunge actions
prior to the weld. The inventer will attempts a weld as soon as it detects
contact between the stud and work piece or af- ter the number of pecks
is performed. When zero, pecking is disabled.
Summary of Contents for N800iTM
Page 18: ......