Stud welding unit N1500i
Version 1.31 7.June.2013
Manual part number: 729-110-027
1
Nelson Stud
Welding, Inc. • 7900 West Ridge Road • Elyria, Ohio 44035 • USA
1
Connection and Installation
1.1
Installation Precautions
Attention must be paid to the fact that the welding unit is installed on
horizontal, vibration-free and non-slip floor space The load-carrying
capacity of the floor space should be at least double the weight of the
welding unit.
When working in high-lying locations, such as bridges, ladders or plat-
forms the N1500i must be secured against the risk of falling.
The Nelweld N1500i must be adequately protected against the intrusi-
on of liquids. It may not be installed on liquid-bearing pipelines.
In order to guarantee unimpeded temperature exchange with the envi-
ronment, a minimum clearance of 1 m (39.4 inch) to existing heat sour-
ces must be observed.
Attention must be paid to the fact that the ventilation slits on the unit
casing are kept free.
1.2
Connection
With the exception of the input power cable all the connecting elements
are arranged in a functional manner on the front plate of the N1500i.