F code
Description
Possible Values
Default
Unit
Notes
F63
Pecker Mode
0 to 20
0
# of
Pecks
Increase the number of pecks to perform a series of
lift-plunge actions prior to the weld. The inverter
will attempt a weld as soon as it detects contact
between the stud and work piece or after the number
of pecks is performed. When zero, pecking is
disabled.
F64
Fieldbus Selection
OFF, Van Rob, Ford, GM
OFF
X
For automated systems, select the appropriate
fieldbus selection to determine the IO map and
sequence of signals. For standard mode, disable this
F code.
F65
Weld Complete 24V
Signal
OFF ON
OFF
X
For automated systems, this output signal is given
after each weld to indicate that the weld was
successful. The signal is 24VDC (unregulated),
active high, 500ms long.
F66
Diagnostic Mode
0 to 4
0
X
Factory use only.
Other features:
•
To enter/exit demo mode, press 1,2, and 3 simultaneously. This will disable welding and flash LEDs.