background image

 

For harness, please follow this diagram:

  

 

 

Note:  the  first  conductor 

B

LACK 

“1”

  that  should  be  connected  to  the  + 

(positive) C

LOSES

 the window; the second conductor 

Black “2”

 that should be 

connected to the + (positive) O

PENS

 the window; the third conductor 

 Black 

“3”

 is the conductor used for the BK-LOCK control communication signal.

 

9. Instructions for assembly 

These indications are for specialised technical personnel and basic work and 

safety techniques are not indicated. 

All  preparatory,  assembly  and  electrical  connection  operations  must  be  performed 
by specialised technical personnel to guarantee optimal function and service of the 
actuator. Check that the following fundamental conditions have been met: 

 

Before installing the actuator, check that the moving parts of the window on 
which  it  is  to  be  installed  are  in  perfect  working  condition  and  that  they 
open and close properly and are well balanced (where applicable).  

 

Actuator  specifications  must  be  sufficient  for  movement  of  the  window 
without encountering any obstacle. The limits indicated in the technical data 
table  must  not  be  superseded 

(page  7)

  and  the  most  appropriate  stroke 

should  be  selected.  Calculations  should  be  checked  using  the  formula 
indicated on page 6. 

 

Attention.

  Check  that  the  electrical  power  supply  corresponds  to  that 

indicated on the 

TECHNICAL DATA

 label on the machine. 

 

Ensure  that  the  actuator  has  not  been  damaged  during  transport,  first 
visually and then by powering in both directions. 

 

Check that the width of the inside of the window (where the actuator is to 
be  assembled)  is  over  360  mm,  otherwise  the  actuator  should  not  be 
installed.  

 

Check  that  once  the  actuator  has  been  installed,  chain  completely  in,  the 
window  is  perfectly  closed.  If  this  is  not  the  case  the  actuator  will  not 
function correctly as the window will not close correctly.  

24

V

 

10 

9.1. 

Preparation for mounting the actuator 

Before  beginning  to  mount  the  actuator,  depending  on  the  type  of  application,  the 
window frame must be prepared by carrying out the following operations: 

9.2. 

Recessed mounting 

For recessed mounting, the window frame must be prepared by milling and making 
two  holes  as  indicated  in  the  diagram  below.  The  depth  of  the  milling  must  be  at 
least 30 mm. 

 

Then  make  two  Ø4.5  holes  on  the  sash  for  the  attachment  bracket.  The 
measurements are specified in the diagram below. 

 

9.3. 

Surface  mounting  on  top-hung  windows  opening  outwards  or 

bottom-hung windows 

The actuator can also be surface mounted on top-hung windows opening outwards or 
dormer windows and on bottom-hung windows, however for these specific applications 
special  support  brackets  are  required  for  the  actuator  which  must  be  supplied 
separately. The two half-brackets attaching the actuator to the sash, however, are the 
same  standard  brackets  supplied  with  the  actuator  and  included  in  the  package.  To 
prepare the holes on the window frame and sash, use the drilling template included in 
the  package  of  the  special  brackets;  this  template  also  specifies  the  diameter  of  the 
holes and their position in reference to the inner edge of the window frame.  

 

Warning

.  In  order  to  prevent  unpleasant  mishaps  with  the  machine  and 

possible safety hazards, carefully choose the length of the clamping screws 
in  order  to  avoid  damaging  the  power  supply  cables  during  the  mounting 
procedure. 

In order to carry out a cost-effective and precise up-to-standard work, it is best if you 
prepare the following complementary material: small parts, equipment and tools. 

 

Fastening on metal window frames: M4 threaded inserts 

(2 pieces for recessed 

mounting and 4 pieces for surface mounting)

, M4x12 flat head metric screws 

(2 

pieces (4 pieces for surface mounting))

Summary of Contents for KIMO

Page 1: ...they will not generate any danger for persons animals or items Symbols used in the manual DANGER This indication draw the attention about potential dangers for safety and health of peoples and animals...

Page 2: ...nce of the entire system with the applicable standards and to issue CE certification We strongly discourage any use of the actuators other than that specified and therefore in any case the supplier of...

Page 3: ...ws with reduced height The brackets are fixed to the frame during actuator assembly with just two screws Combined with the BK LOCK product and perimeter fittings it constitutes the security lock that...

Page 4: ...y are supplied with a Declaration of Incorporation attached to this booklet with regard to the electrical side they bear marking and come under the LVD and CEM Directives and the other Regulations lis...

Page 5: ...ot the case the actuator will not function correctly as the window will not close correctly 24V 10 9 1 Preparation for mounting the actuator Before beginning to mount the actuator depending on the typ...

Page 6: ...he actuator can also work in combination with the BK LOCK electromechanical lock this operating mode can be selected using dip switch No 4 If the dip switch is set on ON without the lock being connect...

Page 7: ...reverse order 14 Troubleshooting Possible causes of malfunction during installation or use 14 Problem Possible cause Solution Actuator does not work No electricity at feeder Check status of circuit br...

Page 8: ...itati prodotti sono conformi alle disposizioni pertinenti delle seguenti Direttive Furthermore the products listed above complies with the provisions of followings Directives 2014 30 EU Direttiva Comp...