After removing packaging, check for any damage on the appliance. 

 

MAINTENANCE and REPAIRS 
Periodically check the installation by inspecting the cables, springs, rods and 
mechanical parts for wear or damage. Do  not use if repair or adjustment is 
required.  
Disconnect the power supply during cleaning or maintenance operations.  
Do  not  use  solvents  or  jets  of  water  to  wash  the  appliance.  The  appliance 
should not be submerged in water. 
In  the  event  of  breakage  or  malfunction,  switch  the  appliance  off  at  the 
general switch and call for the services of a qualified technician. 
Repairs  should  only  be  performed  by  qualified  personnel  at  assistance 
centres authorised by the manufacturer.  

 

Always  request exclusive use of original  spare parts. Failure to respect this 
condition  could  compromise  safety  and  invalidate  the  benefits  contained  in 
the warranty for the appliance. 

 

In  the  event  of  any  problems  or  queries,  consult  your  agent  or  contact  the 
manufacturer directly. 

2. Technical operating information 

The chain actuator is used to open and close the window by means of a three-link 
steel chain 

(Nekos Patent)

. The movement is achieved with very low-voltage (24V

 

SELV)  electricity  that  powers  a  gear  motor  controlled  by  a  functional  electronic 
device.  Window  opening  can  be  programmed,  and  the  device  allows  excursion  of 
the  chain  to  strokes  of  70,  125,  170  and  210  mm.  For  the  return  stroke,  i.e.,  the 
closing  of  the  window,  the  stroke-end  is  determined  by  an  electronic  process  that 
automatically calculates the required power absorption to produce the movement of 
the  window,  and  therefore  no  settings  are  required.  The  actuator  can  also  be 
installed without the immediate availability of electricity for window movement; in this 
case the actuator will simply hold the window closed after assembly. The structure of 
the  actuator  is  entirely  metal  and  it  is  used  for  room  ventilation.  The  coupling 
between  the  actuator  and  support  brackets  fixed  to  the  window  frame  is  a  quick-
connect coupling that allows the actuator to rotate in order to adapt to the stroke of 
the chain, even on windows with reduced height. The brackets are fixed to the frame 
during  actuator  assembly  with  just  two  screws.  Combined  with  the 

BK-LOCK

 

product and perimeter fittings, it constitutes the security lock that keeps the window 
closed tight and guarantees a high thermal K. 

3. Formulas and recommendations for installation  

3.1. 

Calculation of opening / closure force 

Using the formulas on this page, approximate calculations can be made for the force 
required to open or close the window considering all the factors that determine the 
calculation.  

Symbols used for the calculation  

F (Kg) = Force for opening or closing 

P (Kg)  = 

Weight of the window (mobile sash only)

 

C (cm) = Opening stroke (actuator stroke) 

H (cm) = Height of the mobile sash 

 
 
 
 
 
 
 
 

For horizontal light domes or 

skylights 

 

F = 0,54 x P 

(Eventual  weight  of  snow  or  wind  on  the 
cupola should be calculated separately)

For vertical windows 

 

TOP HUNG WINDOWS

,

 OUTWARD OPENING

 (A) 

 

BOTTOM HUNG WINDOWS

 (B) 

F = 0,54 x P x C : H 

(Eventual  load  of  favourable  or  unfavourable  wind 
on the sash should be calculated separately).

 

3.2. 

Maximum opening based on sash height 

The selection of the actuator stroke should be made based on the height of the sash 
and its application. As a general rule, never select a stroke greater than the height of 
the window frame; select the stroke directly below it. 

 

W

ARNING

.  The actuator is designed to  be recess  mounted  on  the window 

frame. Check that during the stroke the chain does not touch the profile of 
the sash, there are no obstacles to opening the window and the chain does 
not push against the window frame. 

4. Construction and regulatory references 

 

INTENDED  USE

  The  KIMO  chain  actuator  is  designed  and  built  to  open 

and  close  top-hung  windows  opening  outwards,  bottom-hung  windows  or 
up-and-over roof windows. Its use is specifically intended for ventilation, air 
conditioning of rooms and, if used in combination with the BK-LOCK window 
lock, also  as  a  building  security system;  it  is  highly  recommended that  the 
actuator  not  be  used  for  any  other  purpose  unless  approved  by  the 
manufacturer beforehand, with the supplier of the entire system in any case 
retaining sole liability. 

 

The  actuator  is  manufactured  in  accordance  with  the  EC  Directives  and 
Regulations  listed  in  the  attached  Declaration  of  Incorporation  and 
Conformity 

Summary of Contents for KIMO

Page 1: ...they will not generate any danger for persons animals or items Symbols used in the manual DANGER This indication draw the attention about potential dangers for safety and health of peoples and animals...

Page 2: ...nce of the entire system with the applicable standards and to issue CE certification We strongly discourage any use of the actuators other than that specified and therefore in any case the supplier of...

Page 3: ...ws with reduced height The brackets are fixed to the frame during actuator assembly with just two screws Combined with the BK LOCK product and perimeter fittings it constitutes the security lock that...

Page 4: ...y are supplied with a Declaration of Incorporation attached to this booklet with regard to the electrical side they bear marking and come under the LVD and CEM Directives and the other Regulations lis...

Page 5: ...ot the case the actuator will not function correctly as the window will not close correctly 24V 10 9 1 Preparation for mounting the actuator Before beginning to mount the actuator depending on the typ...

Page 6: ...he actuator can also work in combination with the BK LOCK electromechanical lock this operating mode can be selected using dip switch No 4 If the dip switch is set on ON without the lock being connect...

Page 7: ...reverse order 14 Troubleshooting Possible causes of malfunction during installation or use 14 Problem Possible cause Solution Actuator does not work No electricity at feeder Check status of circuit br...

Page 8: ...itati prodotti sono conformi alle disposizioni pertinenti delle seguenti Direttive Furthermore the products listed above complies with the provisions of followings Directives 2014 30 EU Direttiva Comp...

Reviews: