A series-parallel configuration increases both voltage (to match the inverter’s DC
requirements) and capacity (to increase run time for operating the loads) using
smaller, lower voltage batteries. In the example below, four 6 VDC/200Ah
batteries are combined into two strings resulting in a 12VDC/400Ah battery bank.
9.4. Best use of Battery Power
Make sure any appliances are energy efficient and turned off after use.
Use Compact Florescent Lamps. Wherever possible, charge with solar panels or
wind generators.
Do not allow lead acid batteries to remain discharged for long periods of time,
they lose capacity (amps hours).
10. MOUNTING AND CONNECTING THE INVERTER
10.1. Mounting The Inverter
Warning:
Keep ventilation when using batteries. Batteries may generate
flammable gas during charging or discharging.
The inverter (1000W to 5000W models) has four slots in its mounting bracket
that allow the unit to be fastened against a bulkhead, floor, wall or other flat
surface. Ideally, the mounting surface should be cool to the touch.
It is more electrically efficient to use longer AC wiring than DC wiring, so install
the inverter as close as possible to the 12 VDC power source.
The inverter can be operated in any position, however, if it is to be mounted on a
wall, mount it horizontally so that indicators, switches, outlets and terminal blocks