background image

1. Make sure that the chassis ground screw on the rear of the inverter is solidly

connected to the ground system of your vehicle or home.

2. Make sure that the television antenna provides an adequate (“snow-free”)

signal and that you are using good quality cable between the antenna and
the television.

3. Keep the cables between the battery and the inverter as short as possible,

and twist them together with two to three twists per foot.( this minimizes
radiated interference from the cables.)

4. Move the television as far away from the inverter as possible.
5. Do not operate high power loads with the inverter which the television is on.

9. CHOOSE THE BATTERY

9.1 Battery Requirements

Battery type and battery size strongly affect the performance of the power
inverter. Therefore, you need to identify the type of loads your inverter will be
powering and how much you will be using them between charges. To determine
the minimum battery size that you need to operate appliances, follow these
steps:
1. Determine the wattage of each appliance and/or tool you will need to

simultaneously operate from the inverter. To do this, read the labels on the
requirement to be operated. Usually, power consumption is shown in watts. If
it is shown in amps, multiply by 220-240V to determine the wattage.

2. Estimate the number of hours the equipment will be in use between battery

recharges.

3. Determine the total watt-hours of energy use, the total running time and the

average power consumption power (in watts) by 10 in 12V system.

4.
To calculate the approximate power a 12 volt battery bank has to supply in amps,
you need to know the current, or amps required for powering the continuous AC
load. A easy method is to divide the continuous AC load wattage by 10.
For example, the continuous AC load is 2000 watts, the current (amps) is:
2000/10 or 200amps at 12VDC.

Notes:

some appliances required high surge power to start, then consumer less

power. And some appliances are not operating for long periods of time. For
example, a typical home-use coffee maker draws 500watts during its brew time
of 5minutes, but it maintains the temperature of the pot at about 100watts.
Typical use of a microwave is only a few minutes, sometimes at lower power;

Summary of Contents for CAR2K

Page 1: ...ing the product are the original instructions This document is part of the product keep it for the life of the product passing it on to any subsequent holder of the product Read all these instructions...

Page 2: ......

Page 3: ...lose its validity Product description 2000W POWER INVERTER Model CT1398 Ref no CAR2K Product description 3500W POWER INVERTER Model CT1399 Ref no CAR3 5K Applicable EC Directives GPSD Directive The Ge...

Page 4: ......

Page 5: ...ICATION Model CT1398 CT1399 Output Rated power 2000W 3500W Surge power few seconds 4000W 7000W Voltage AC 220 240V AC Voltage Regulation 10 Frequency Hz 50Hz Waveform modified sine wave USB port 5V Ma...

Page 6: ...damaged or substandard wiring Make sure that all wiring is in good condition and is not undersized Fail to follow these instructions will result in death or serious injury Notes Turning off the invert...

Page 7: ...r other connections between components of the fuel system Precautions when placing the inverter CAUTION Risk Of Damage To The Inverter Never allow battery acid to drip on the inverter when reading gra...

Page 8: ...nverter down automatically if its internal temperature rises above an unacceptable level Output short circuit shutdown Shuts the inverter down automatically if a short circuit is detected in the circu...

Page 9: ...kind of electrical equipment including the inverter in these areas Protected from battery gases The inverter should be installed as close as possible to the batteries but not in the same compartment t...

Page 10: ...eakage or fault happen 4 Power light green indicates the inverter is operating 5 USB port it output DC5V 2 1A connect the USB external appliance to USB port and switch it on The USB output on the powe...

Page 11: ...ooling fan must not be obstructed for the proper operation of the inverter When the inverter is mounted then ventilation opening on the DC panel must not point up or down 10 DC cable with ring there i...

Page 12: ...rectly They will read about 20 to 30 volts low when measuring the output of the inverter For accurate measurement of the output voltage of this unit use a true RMS reading voltmeter such as Fluke 87II...

Page 13: ...e wattage of each appliance and or tool you will need to simultaneously operate from the inverter To do this read the labels on the requirement to be operated Usually power consumption is shown in wat...

Page 14: ...ime Battery capacity Ah Input voltage Volt loads power Watt For example Battery capacity 150Ah Input voltage 12Volt Loading power 600Watt So 150Ah 12V 600Watt 3 hours Note the time calculated by this...

Page 15: ...Ah batteries are combined into a single string resulting in a 12VDC 200Ah bank b Parallel Wiring Wiring the batteries in parallel increases the total run time the batteries can operate the AC loads A...

Page 16: ...long periods of time they lose capacity amps hours 10 MOUNTING AND CONNECTING THE INVERTER 10 1 Mounting The Inverter Warning Keep ventilation when using batteries Batteries may generate flammable gas...

Page 17: ...describe all of the possible types of battery configurations battery charging configuration and battery isolation configurations The figure as below show the typical connection Note For safety concern...

Page 18: ...nections Do not over tighten 11 OPERATING THE AC APPLIANCES 1 When you have confirmed that the AC appliances to be operated is turned off plug an appliance cord into the AC outlet on the front panel o...

Page 19: ...er s rating power if the power consumption is rated in amps simply multiply by the AC volts 220 240V to determine the wattage The inverter will shutdown if it is overloaded To overload must be removed...

Page 20: ...Please replace the fuse by same size as burn one Normally after you replace the new fuse the inverter recovers automatically But sometimes there is a kind of special condition even after you replace t...

Page 21: ...ction circuit Reduce load or remove short circuit The AC voltage you measured too lower Possible Cause Suggested Solution The voltmeter you used not a true RMS meter Change to use a true RMS voltmeter...

Page 22: ...rm sounds Possible Cause Suggested Solution Low battery voltage Recharge or replace battery AC appliances won t start Possible Cause Suggested Solution Excessive start up load If appliances does not s...

Page 23: ...is appliance please take it to the applicable collection point or deliver it to a public recycling location of old electronic equipment Electronic equipment should not be disposed as normal household...

Page 24: ...CANNON TOOLS LTD Add 20 station road Rowley Regis west midlands B65 0JU U K Made in China...