7. STOP YOUR GENERATING SET
1. Disconnect the load from the generating set.
2. Turn off the air switch of the generating set.
3. Set the speed lever at
“RUN” POSITION, run
the generating set without load for about 3
minutes. Do not stop the engine suddenly,
otherwise the temperature will be damaged.
Press down stop lever.
Concerning the electric starter, turn the
key to
“OFF”
Turn the fuel cock lever to
“S” position.
Pull out the recoil starter handle until you
feel resistance (at the position, both
intake/exhaust valve are closed.) and
leave the handle in this position. This
prevents the engine from rust.
If the engine keep on running even after the speed lever is placed at the
“STOP”
position, either turn the fuel cock to the
“CLOSE” position or loosen the nut of high
pressure fuel pipe on the pump side to stop the engine.
Do not stop the engine with the decompression lever.
Do not stop the generating set with load. Stop it after the load removed.
With engine speed level
at STOP position
stop lever
WARNING
Summary of Contents for BDE2200E
Page 12: ...2 1 Parts name BDE series E X type...
Page 13: ...2 1 Parts name BDE series T type...
Page 21: ......
Page 22: ......
Page 36: ...Electric Wiring Diagram for All Types of the Set 1 C type electric wiring diagram...
Page 37: ...2 X type electric wiring diagram single voltage output...
Page 38: ...3 X type electric wiring diagram double voltage output...
Page 39: ...4 E type electric wiring diagram single voltage output...
Page 40: ...5 E type electric wiring diagram double voltage output...
Page 41: ...6 T type electric wiring diagram...
Page 43: ...8 X3 E3 type electric principle diagram...
Page 44: ...CANNON TOOLS LTD 20 Station Road Rowley Regis West Midlands B65 0JU U K Made in China...