background image

 

 
 

  For the generating set with Low Oil Warning System, the Oil Alarm Lamp 

will activated by low oil pressure or engine oil shortage, simultaneously, 

the engine will stop. The engine will stop immediately if restarted without 

refilling the engine oil. Check the oil level and refill. 

  Do not loosen or readjust either the engine speed limiting bolt or fuel injection bolt, 

otherwise , the performance will be affected. 

 

5.2 Checks during the running 

 

1. Whether there is abnormal sound or vibration; 

2. Whether the engine misfires or runs rough; 

3. Check the color of the exhaust.(Is it black or too white?) 

    If you notice any of the above-mentioned phenomenon happened, stop the engine and find 

out the fault cause or contact with agent. 

 

 

 

 

  If the engine has been running, the muffler will be vary hot. Be careful not to touch the 

muffler. 

  Never refill the fuel tank while the engine is running. 

 

 
 

    6. LOAD 

 
 

 
 

  Do not start 2 or more machines simultaneously. Start them one by one. 

  Do not use floodlights together with other machines. 

 

 
 
 
 

CAUTION 

CAUTION 

CAUTION 

Summary of Contents for BDE2200E

Page 1: ...SINGLE PHASE BDE2200E BDE3500E BDE5000E BDE6500TW BDE6700T BDE6500T BDE6700TN BDE6500TW3 BDE6700T3 BDE6500T3 BDE6700TN3 PLEASE READ THIS MANUAL CAREFULLY IT CONTAINS IMPORTANT SAFETY INFORMATION ORIGI...

Page 2: ...reed upon by us this declaration will lose its validity Product description Diesel Generator Model CT2020 CT1848 CT1788 CT0405 CT3998 CT0012 CT3999 BDE2200E BDE3500E BDE5000E BDE6500TW BDE6700T BDE650...

Page 3: ...verloading the generator poses a risk and can lead to serious damage and or injury Disconnect the generator before carrying out any kind of maintenance Let the engine reach full speed before connectin...

Page 4: ...store this generator correctly never use or store this generator on it s side as oil or fuel may leak and damage the generator or your property If the generator has been used always allow it to cool f...

Page 5: ...ny fuel spilling may cause a fire disaster d No refueling when the engine is working Refueling the generator when it is working will cause a fire e Be sure wipe out the spilling oil for afraid of Fire...

Page 6: ...aust fumes contain carbon monoxide Carbon monoxide can be extremely dangerous or even fatal Never run the generator indoors Only operate the machine in well ventilated areas The exhaust fumes produced...

Page 7: ...sure the area is well ventilated Periodic maintenance and adjustment is necessary to keep the generator in good operating condition Perform the service and inspection at the intervals shown in the Ma...

Page 8: ...3600 Single phase 1 12V 8 3A 170 190 E 720X480X645 T 910X520X740 50 4 6 230 115 20 40 3000 BDE5000E 60 5 240 120 20 8 41 7 3600 Single phase 1 12V 8 3A 139 E 720X480X645 T 910X520X740 50 4 2 230 115 1...

Page 9: ...starter Diesel 0 summer 10 winter 15 30 With 5 7 6 25 BDE6500TW BDE6500T BDE6700T BDE6700TN 186 6 25 6 88 86 x 72 406 1 65 15 30 5 7 6 25 BDE5000E 186 6 3 6 6 86 x 70 406 1 65 CX Recoil starter T E E...

Page 10: ...ade or industrial applications Our warranty will be voided if the machine is used in commercial trade or industrial businesses or for equivalent purposes Before putting the machine into operation 1 El...

Page 11: ...When starting with the reserve starter the motor may recoil suddenly as it starts up resulting in hand injuries Wear protective gloves when starting the equipment 2 Connecting consumers to the genera...

Page 12: ...2 1 Parts name BDE series E X type...

Page 13: ...2 1 Parts name BDE series T type...

Page 14: ...2 Control panel C type panel E type panel E model receptacle panel E3 type three phase panel EW welding panel E type basic model panel E type panel A model double voltage panel Intelligent control pan...

Page 15: ...ilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or where the fuel oil stored Do not overfill the tank make sure the filler cap is se...

Page 16: ...seizure piston ring sticking and accelerated wear of the cylinder liner bearing and other moving components increases significantly So the generating set life will be shortened Recommends CC CD oil c...

Page 17: ...1 Turn off the main switch and any other Loads WARNING Be sure to turn off the main switch before starting The generating set should be earthed to prevent electric shocks WARNING The generating set sh...

Page 18: ...n the engine is started could be very dangerous 3 5 How to open the cabinet door and covers of LDE series generating set 1 Open the cabinet door for daily inspection Turn the lever counterclockwise an...

Page 19: ...ime Replace the engine oil while the engine is warm after 20 hours running the old engine oil will be drained out completely 4 START THE GENERATING SET Do not hook up tools or other apparatus to the g...

Page 20: ...not allow the handle grip to snap back against the engine Return it gently to prevent damage to the starter When the engine is difficult to start in cold weather remove the screw plug from the cylind...

Page 21: ......

Page 22: ......

Page 23: ...START position Remove your hand from the key as soon as the engine starts If the starting motor doer not start after 10 seconds wait 15 seconds before starting it again Run the starting motor for long...

Page 24: ...is not sufficient power On the other side if the electrolyte level is too high the fluid will corrode the surrounding parts Do keep the electrolyte level between the upper and lower limits 5 OPERATE T...

Page 25: ...2 Checks during the running 1 Whether there is abnormal sound or vibration 2 Whether the engine misfires or runs rough 3 Check the color of the exhaust Is it black or too white If you notice any of th...

Page 26: ...the matter of the motor load firstly the heavy duty motor should be connected then the light duty motors If the operation is false the generating set will lag or stop suddenly It is necessary to unlo...

Page 27: ...ill result Do not connect the positive pole of the DC terminal with its negative pole otherwise the generating set damage will result When a large capacity battery is charged excessive current flows t...

Page 28: ...us to the generating set TYPE WATTAGE TYPICAL APPLIANCE EXAMPLE STARTING RATED APPLIANCE STARTING RATED Incandescent lamp Heating appliance X 1 X 1 Incandescent lamp Incandescent lamp 100W 100VA W 100...

Page 29: ...sition Pull out the recoil starter handle until you feel resistance at the position both intake exhaust valve are closed and leave the handle in this position This prevents the engine from rust If the...

Page 30: ...1000Hrs Check and refill fuel oil Drain out fuel oil Check and refill fuel oil Check for oil leakage Check and tighten fastening parts Tighten the cylinder head bolts Replace engine oil First time sec...

Page 31: ...eplace if necessary 8 3 Replace the air cleaner clement Do not clean the air cleaner element with detergent Replace time Every 6 months or 500 hours Never run the engine without the element or with a...

Page 32: ...ourself Contact with agent 8 6 Check the injection nozzle and fuel injection pump 1 Adjust the clearance of the intake exhaust valves 2 Grind the intake exhaust valves 3 Replace the piston ring All th...

Page 33: ...vered replace the battery Check the battery electrolyte monthly The battery electrolyte contains sulfuric acid Protect your eyes skin and clothing In case of contact flush thoroughly with water and ge...

Page 34: ...ush the decompression lever down Non compression position and hold it while you pull the recoil starter 2 3 times Do not start the engine Electric starting Turn the engine 2 3 seconds with the decompr...

Page 35: ...brush The contact of the socket is not good Adjust the socket The rated speed can not attached Adjust it according to the requirements AVR is damaged Replace the AVR Meaning of crossed out wheeled du...

Page 36: ...Electric Wiring Diagram for All Types of the Set 1 C type electric wiring diagram...

Page 37: ...2 X type electric wiring diagram single voltage output...

Page 38: ...3 X type electric wiring diagram double voltage output...

Page 39: ...4 E type electric wiring diagram single voltage output...

Page 40: ...5 E type electric wiring diagram double voltage output...

Page 41: ...6 T type electric wiring diagram...

Page 42: ...7 X3 E3 type electric principle diagram Description For set X3 type the components in the two point and line box are not mounted...

Page 43: ...8 X3 E3 type electric principle diagram...

Page 44: ...CANNON TOOLS LTD 20 Station Road Rowley Regis West Midlands B65 0JU U K Made in China...

Reviews: