background image

3

Appliance description

Operating modes

Exhaust-air mode:

The extractor-hood fan extracts the 
kitchen vapours and conveys them
through the grease filter into the 
atmosphere.

The grease filter absorbs the solid 
particles in the kitchen vapours.

The kitchen is kept almost free of grease
and odours.

D

When the extractor hood is operated

in exhaust-air mode simultaneously with
a different burner which also makes use
of the same chimney 

(such as gas, oil or

coal-fired heaters, continuous-flow heaters,
hot-water boilers) care must be taken to

ensure that there is an adequate supply
of fresh air 

which will be needed by the

burner for combustion.

Safe operation is possible provided that the
underpressure in the room where the
burner is installed does not exceed 4 Pa
(0.04 mbar).

Operating modes

This can be achieved if combustion air can
flow through non-lockable openings, e.g. in
doors, windows and via the air-
intake/exhaust-air wall box or by other
technical measures, such as reciprocal
interlocking, etc.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.

Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.

Unrestricted operation is possible if the
extractor hood is used in recirculating mode
– with activated carbon filter.

Circulating-air mode:

An activated carbon filter must be fitted
for this operating mode (see Filters and
maintenance).

The complete installation set and 

replacement filters can be obtained 

from 

specialist

outlets.

The corresponding accessory numbers
can be found at the end of these 
operating instructions.

The extractor-hood fan extracts the 
kitchen vapours which are purified in the
grease filter and activated carbon filter
and then conveyed back into the 
kitchen.

The grease filter absorbs the grease 
particles in the kitchen vapours.

The activated carbon filter binds the
odorous substances.

If no activated carbon filter is installed, 

it is not possible to bind the odorous 
substances in the cooking vapours.

Instructions for use:

Light 

Filter grille

Chimney
panelling

Light / fan 

switches

Summary of Contents for D86M35N0GB

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D96M6N0 D99M6N0 NEFF UK Ltd...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ...

Page 3: ...stion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the...

Page 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Page 5: ...ance Grease filters Metal filters are used to trap the greasy element of the vapours that develop during cooking The filter mats are made from non combustible metal Caution As the filter becomes more...

Page 6: ...as part of your normal domestic refuse Installation and removal Warning The halogen bulbs must be switched off and cool 1 Remove the metal mesh filters see Removing and inserting the metal mesh greas...

Page 7: ...hlorine Clean the extractor hood with a hot soap solution or a mild window cleaner Do not scrape off dried on dirt but wipe off with a damp cloth When cleaning the grease filters remove grease deposit...

Page 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Page 9: ...the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air ca...

Page 10: ...nternal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exha...

Page 11: ...onnector If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be connected to the electricity supply by a properly qualified electrician A separator mus...

Page 12: ...e hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes...