background image

10

Prior to installation

For optimum extractor hood efficiency:

Short, smooth air exhaust pipe.

As few bends in the pipe as possible.

Diameter of pipe to be as large as
possible and no tight bends in pipe.

If long, rough exhaust-air pipes,
many pipe bends or smaller pipe 
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.

The manufacturer of the 

extractor hoods accepts no liability 
for complaints which can be 
attributed to the design and layout of 
the pipework.

Round pipes:

We recommend
Internal diameter: 

150 mm

(at least

120 mm).

Flat ducts 

must have an internal cross-

section that equates to that of round
pipes.

There should be no sharp bends.

l

120 mm approx. 113 cm

2

l

150 mm approx. 177 cm

2

If pipes have different diameters:

Insert sealing strip.

For exhaust-air mode, 

ensure that

there is an adequate supply of fresh air.

Circulating-air mode

With activated carbon filter if exhaust-air
mode is not possible.

Connecting a 

l

150 mm exhaust-air

pipe:

Mount the pipe directly onto the air
outlet on the hood.

Connecting a 

l

120 mm exhaust-air

pipe:

Attach the reducing connector directly to
the air pipe.

The complete

installation set can be
obtained 

from 

specialist

outlets.

The corresponding
accessory numbers
can be found at the
end of these operating
instructions.

Attach the exhaust-air pipe to the 
reducing connector.

55

770-1130

280

260

550

600

mind. 135

mind. 600

40

500

900

600

Summary of Contents for D86M35N0GB

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D96M6N0 D99M6N0 NEFF UK Ltd...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ...

Page 3: ...stion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the...

Page 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Page 5: ...ance Grease filters Metal filters are used to trap the greasy element of the vapours that develop during cooking The filter mats are made from non combustible metal Caution As the filter becomes more...

Page 6: ...as part of your normal domestic refuse Installation and removal Warning The halogen bulbs must be switched off and cool 1 Remove the metal mesh filters see Removing and inserting the metal mesh greas...

Page 7: ...hlorine Clean the extractor hood with a hot soap solution or a mild window cleaner Do not scrape off dried on dirt but wipe off with a damp cloth When cleaning the grease filters remove grease deposit...

Page 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Page 9: ...the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air ca...

Page 10: ...nternal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exha...

Page 11: ...onnector If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be connected to the electricity supply by a properly qualified electrician A separator mus...

Page 12: ...e hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes...

Page 13: ...anelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template use...

Page 14: ...14 Notes...

Page 15: ...15 360732 Z 5116X5 1 2 3 4 5 6 2x 10x 2x...

Page 16: ...9000 136 100 Printed in Germany 0206 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...