Installation Instructions:

Additional information concerning gas
cookers:

When installing gas hotplates, comply

with the relevant national statutory 
regulations (e.g. in Germany: Technische
Regeln Gasinstallation TRGI).

Always comply with the currently valid

regulations and installation instructions
supplied by the gas appliance 
manufacturer.

Only one side of the extractor hood

may be installed next to a high-sided unit
or high wall. Gap at least 50 mm.

Minimum distance on gas hotplates

between the upper edge of the trivet 
and lower edge of the extractor 
hood:     

650 mm, 

Fig. 1.

Old appliances are not worthless

rubbish. Valuable raw materials can be
reclaimed by recycling old appliances.
Before disposing of your old appliance,
render it unusable.

You received your new appliance in a

protective shipping carton. All packaging
materials are environmentally friendly and
recyclable. Please contribute to a better
environment by disposing of packaging
materials in an environmentally-friendly
manner.

Please ask your dealer or inquire at your
local authority about current means of 
disposal. 

The extractor hood can be used in

exhaust air or circulating air mode.

Always mount the extractor hood over

the centre of the hob.

Minimum distance between electric

hob and bottom edge of extractor hood:

550 mm,

Fig. 1.

The extractor hood must not be 

installed over a solid fuel cooker – a 
potential fire hazard (e.g. flying sparks) –
unless the cooker features a 

closed, 

non-removable cover

and all national

regulations are observed.

The smaller the gap between the

extractor hood and hotplates, the greater
the likelihood that droplets will form on the
underside of the extractor hood.

Summary of Contents for D8642N0

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D8642N0 D8742N0 D8942N0 NEFF UK Ltd ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Page 3: ... is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and oven...

Page 4: ...or infirmed persons without supervision Young children should be supervised to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user Dispose of packaging materials properly see Installation instructions This...

Page 5: ...leaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they will become slightly discoloured The filter must be placed loosely and NOT wedged in the dishwasher Important Metal filters that are saturated with grease should not be washed together with other dishes etc When cleaning the filters by hand soak them in hot soapy water first of all Do not use aggressive...

Page 6: ...efuse Filters and maintenance 2 Clean the filters 3 Insert the clean filters back into the hood Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more and more saturated with grease there is an increased risk of fire and the function of the extractor hood may be impaired Important Change the activated carbon filter promptly to prevent the risk of f...

Page 7: ...rt but wipe off with a damp cloth When cleaning the grease filters remove grease deposits from accessible parts of the housing This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency Note Do not use alcohol spirit on plastic surfaces as dull marks may appear Caution Ensure that the kitchen is ade quately ventilated Avoid naked flames Clean the o...

Page 8: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in ex...

Page 9: ...f fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking ...

Page 10: ...maller pipe diameters are used the air extraction rate will no longer be at an optimum level and there will be an increase in noise The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh ai...

Page 11: ...lack 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly behind the chimney panelling The earthed socket should be connected via its own circuit If the earthed socket is no longer accessible following installation...

Page 12: ...s hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling Insert plugs into the holes so that they are flush with the wall Note Take into account any special accessories that are going to be fitted 5 Attach the 2 enclosed spacers to the fixing bracket for the flue duct panelli...

Page 13: ... the flue panelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 09 Connect up the air outlet pipe 10 Connect the hood to the electricity supply 13 Slide out the upper section and attach it to...

Page 14: ...14 Notes ...

Page 15: ...15 1 2 3 4 5 6 2x 10x 2x 7 361047 Z5123X5 ...

Page 16: ...9000 152 338 Printed in Germany 0406 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399 ...

Reviews: