background image

Page 9 of 12

RS-232/IR port

The RS-232/IR port (TX-2) is used for one-way RS232 or IR 

communication depending on the setup made in Neets Project 

Designer. 

Be aware that the port can’t be used as RS232 and IR port at 

the same time.

 

Connect the port as shown below.

NEB port

The EcHo Plus has a built-in NEB (Neets Extension Bus). This 

port is used to add up to 2 NEB devices (e.g. two Keypads, two 

Level Controls and one Expander). 

Connect your NEB devices to this port with a cable not  

exceeding 20 cm of length. PWR to PWR, NCL to NCL, NDA to 

NDA and GND to GND.

If additional cable length is needed in your application, please 

use the NEB extender to allow placement of the devices up 

to 40 meters from the EcHo Plus. See the Neets website for 

details on the NEB Extender.

Neets Control

EcHo Plus, DK

P/N: 310-0252

LAN

GND

GND

I/O 1

I/O 2

I/O 3

PWR

NDA

NCL

GND

GND

TX-1

TX-2

RX-1

GND

12V

Neets Control

EcHo Plus, DK

P/N: 310-0252

LAN

GND

GND

I/O 1

I/O 2

I/O 3

PWR

NDA

NCL

GND

GND

TX-1

TX-2

RX-1

GND

12V

When used as single IR port: 

Connect the IR emitter to 

TX-2 (white striped wire) and 

GND, as shown above.

When used as RS-232 

transmit port: Connect the 

device to TX-1 and GND, as 

shown above.

When used as dual IR port: 

Connect the IR 1 emitter to 

TX-2 (white striped wire) and 

black wire on IR 1 emitter to 

IR 2 emitter (white striped 

wire), and black wire from IR 

2 emitter to GND, as shown 

above.

Neets Control

EcHo Plus, DK

P/N: 310-0252

LAN

GND

GND

I/O 1

I/O 2

I/O 3

PWR

NDA

NCL

GND

GND

TX-1

TX-2

RX-1

GND

12V

Neets Control

EcHo Plus, DK

P/N: 310-0252

LAN

GND

GND

I/O 1

I/O 2

I/O 3

PWR

NDA

NCL

GND

GND

TX-1

TX-2

RX-1

GND

12V

Neets Control

EcHo Plus, DK

P/N: 310-0252

LAN

GND

GND

I/O 1

I/O 2

I/O 3

PWR

NDA

NCL

GND

GND

TX-1

TX-2

RX-1

GND

12V

PIN 5 <-> GND

PIN 2 <-> Tx

Junction

Summary of Contents for echo plus

Page 1: ...Neets Control EcHo Plus EcHo Plus EU P N 310 0152 EcHo Plus DK P N 310 0252 User Manual...

Page 2: ...ge the specification and functions of this product without any notice Check www neets dk for the latest updated version ogf this manual Questions AFTER reading this manual can be addressed to your loc...

Page 3: ...components inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moistu...

Page 4: ...t 3 Contents 4 Description 5 Specifications 6 Quick guide to the EcHo Plus 7 Connections and Controls 8 Power input port 8 I O ports 8 RS 232 port 8 RS 232 IR port 9 NEB port 9 LAN port 10 Buttons 10...

Page 5: ...you are ready to begin EcHo Plus is a perfect choice for the classroom meeting or conference room and is easy to install EcHo Plus can control devices through IR RS232 or even LAN EcHo Plus is availa...

Page 6: ...z to 150 KHz Product number 310 0152 EcHo Plus EU 310 0252 EcHo Plus DK Approvals IEC EN 61000 6 1 IEC EN 61000 6 2 Input Output Ports 3 x I O Input trigger low 1VDC Input trigger high 4VDC Output typ...

Page 7: ...el glass with label for button description 4 Mini USB for programming behind front glass Rear Number Description 1 RS 232 port Bi directional 2 RS 232 or IR port Uni directional 3 NEB bus port 4 Input...

Page 8: ...through a FET transistor also called open drain collector function Each I O can draw up to 24VDC 500mA When used as inputs the applied voltage must be below 1 VDC to be accepted as LOW and above 4 VDC...

Page 9: ...ol EcHo Plus DK P N 310 0252 LAN GND GND I O 1 I O 2 I O 3 PWR NDA NCL GND GND TX 1 TX 2 RX 1 GND 12V Neets Control EcHo Plus DK P N 310 0252 LAN GND GND I O 1 I O 2 I O 3 PWR NDA NCL GND GND TX 1 TX...

Page 10: ...V system Button function and LED indication are set up using the Neets Project Designer software USB port The USB port is used exclusively for configuring the EcHo Plus from the Neets Project Designer...

Page 11: ...ject are connected o Check that the NEB units used in the project are configured correctly o After doing one of the above remove the power to the control system for 20 sec before recon necting the pow...

Page 12: ...or more of the Neets network units used in the current project needs a firmware upgrade before it will work with this project 1 Off 2 Off 3 Flashing 4 Off Error in serial number o You need to return...

Reviews: